MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.216.2.r00au36545

Медицинская библиотека · Radiology · 2000

Breast lesions: evaluation with dynamic contrast-enhanced T1-weighted MR imaging and with T2*-weighted first-pass perfusion MR imaging.

Kvistad K A, Rydland J, Vainio J, Smethurst H B, Lundgren S, Fjøsne H E, Haraldseth O

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To evaluate the diagnostic value of an imaging protocol that combines dynamic contrast-enhanced T1-weighted magnetic resonance (MR) imaging and T2*-weighted first-pass perfusion imaging in patients with breast tumors and to determine if T2*-weighted imaging can provide additional diagnostic information to that obtained with T1-weighted imaging.

MATERIALS AND

METHODS

One hundred thirty patients with breast tumors underwent MR imaging with dynamic contrast-enhanced T1-weighted imaging of the entire breast, which was followed immediately with single-section, T2*-weighted imaging of the tumor.

RESULTS

With T2*-weighted perfusion imaging, 57 of 72 carcinomas but only four of 58 benign lesions had a signal intensity loss of 20% or more during the first pass, for a sensitivity of 79% and a specificity of 93%. With dynamic contrast-enhanced T1-weighted imaging, 64 carcinomas and 19 benign lesions showed a signal intensity increase of 90% or more in the first image obtained after the administration of contrast material, for a sensitivity of 89% and a specificity of 67%.

CONCLUSION

T2*-weighted first-pass perfusion imaging can help differentiate between benign and malignant breast lesions with a high level of specificity. The combination of T1-weighted and T2*-weighted imaging is feasible in a single patient examination and may improve breast MR imaging.

Для цитирования: Kvistad K A, Rydland J, Vainio J, Smethurst H B, Lundgren S, Fjøsne H E, Haraldseth O. Breast lesions: evaluation with dynamic contrast-enhanced T1-weighted MR imaging and with T2*-weighted first-pass perfusion MR imaging.. Radiology. 2000. DOI: 10.1148/radiology.216.2.r00au36545.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.