The clinical significance of electronic fetal heart rate monitoring in twins.

Dera-Szymanowska Anna, Polska Martyna, Markwitz Wieslaw, Moczko Jerzy, Horst Nikodem, Szymanowski Krzysztof

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Fully effective intrapartum cardiotocographic (CTG) fetal heart monitoring is still missing. Visual analysis is far from credibility. Additional, computerized analysis techniques were proposed however they did not substantially decrease possible risks of fetal asphyxia. In twin pregnancies the problem is even more complicated. Our goal is to find the most valuable parameters in intrapartum CTG surveillance in twins, based on actual FIGO criteria.

MATERIAL AND

METHODS

Study included 58 women in labor who had been admitted to Delivery Department of tertiary care hospital with twin pregnancy in a period of one year. The features of the CTG (e.g., baseline, oscillation, decelerations, brady- or tachycardia) were grouped to create three variables that were closest to the FIGO CTG scale. All three groups were compared according to neonatal status (Apgar score at 5 min ≥ 7 or < 7; pH value in umbilical artery ≥ 7.20, < 7.20 or < 7.10 and BE (base excess) > or ≤ -12). Fetal status and its acid - base equilibrium was compared either with long term variability (LTV), short term variability (STV), or percentage of the signal loss.

RESULTS

Out of 58 twin pregnancies, a total of 116 babies were born. One baby was born dead. From this group, 11 deliveries were natural births and 47 deliveries were C-sections. None of the analyzed features (pH, BE, Apgar, CTG features except tracing length, CTG FIGO categories) were statistically different between groups of singleton and twin pregnancies, except percentage of C-sections. No differences were found either for STV or LTV and fetal status.org CTG categories.

CONCLUSIONS

Prior to cardiotocographic tracing of twins during labor, ultrasound examination should be mandatory. Considerable loss of signal in CTG tracing in twins should provoke ultrasonographic confirmation of the fetal status.

Для цитирования: Dera-Szymanowska Anna, Polska Martyna, Markwitz Wieslaw, Moczko Jerzy, Horst Nikodem, Szymanowski Krzysztof. The clinical significance of electronic fetal heart rate monitoring in twins.. Ginekologia polska. 2022. DOI: 10.5603/gp.a2022.0129.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.