Improvement in Atrial Fibrillation Detection by Pulse Checking of Patients with Non-Cardioembolic Stroke in Rehabilitation Hospitals: The ESCORT Study.

Katano Takehiro, Suda Satoshi, Ohta Tomohiro, Miyagami Mitsusuke, Kodaira Yuzo, Konaka Chimori, Nagashima Masakazu, Kimura Kazumi

СтатьяНаблюдательное исследованиеМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Rehabilitation therapists are sometimes unaware of the possibility of undiagnosed atrial fibrillation (AF) and the importance of AF detection. Thus, we aimed to increase awareness among rehabilitation therapists of the importance of AF detection at rehabilitation hospitals during regular pulse checks of patients with ischemic stroke.

METHODS

In this multicenter prospective observational study, we enrolled patients with noncardiac stroke. The therapists performed pulse checks before, during, and after rehabilitation during the inpatient period. Electrocardiography (ECG) was performed to check for AF when arrhythmia or tachycardia was detected. The characteristics, ECG data, laboratory data, complications such as stroke recurrence, and functional outcomes of the patients were investigated.

RESULTS

Among 158 included patients (97 [61.4%] men, median age 77 [interquartile range {IQR}, 71-84] years), the median stay in stroke centers was 21 (IQR,15-31) days. Regarding medication administered upon admission, 94 (59.5%) patients received single antiplatelet therapy and 14 (8.9%) patients received no antithrombotic medication. Electrocardiography and blood testing were performed on admission in 112 (70.9%) and 136 (87.3%) patients, respectively. The median hospitalization period in the rehabilitation center was 179 (IQR, 90-272) days. Four patients (2.5%) experienced recurrent events. No patients developed AF or palpitations.

CONCLUSIONS

Although our results suggest increased awareness of AF detection in rehabilitation centers, AF was not detected. AF detection using pulse checks alone may be challenging; thus, further investigation is warranted.

Для цитирования: Katano Takehiro, Suda Satoshi, Ohta Tomohiro, Miyagami Mitsusuke, Kodaira Yuzo, Konaka Chimori, Nagashima Masakazu, Kimura Kazumi. Improvement in Atrial Fibrillation Detection by Pulse Checking of Patients with Non-Cardioembolic Stroke in Rehabilitation Hospitals: The ESCORT Study.. Journal of Nippon Medical School = Nippon Ika Daigaku zasshi. 2024. DOI: 10.1272/jnms.jnms.2024_91-612.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.