MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/tvst.12.1.14

Медицинская библиотека · Translational vision science & technology · 2023

Corneal Biomechanical Characteristics in Osteogenesis Imperfecta With Collagen Defect.

Chou Chien-Chih, Shih Po-Jen, Jou Tzuu-Shuh, Hsu Min-Yen, Chen Jun-Peng, Hsu Rai-Hseng, Lee Ni-Chung, Chien Yin-Hsiu, Hwu Wuh-Liang, Wang I-Jong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To identify the characteristic corneal biomechanical properties of osteogenesis imperfecta (OI), and to compare the corneal biomechanical properties between OI and keratoconus.

METHODS

We included 46 eyes of 23 patients with OI, 188 eyes of 99 keratoconus patients, and 174 eyes of 92 normal controls to compare corneal biomechanical parameters between OI corneas, keratoconus, and normal controls by using Corneal Visualization Scheimpflug Technology (Corvis ST).

RESULTS

Patients with OI had significantly higher Corvis biomechanical index (CBI) (P < 0.001), higher tomographic and biomechanical index (TBI) (P = 0.040), lower Corvis Biomechanical Factor (CBiF) (P = 0.034), and lower stiffness parameter at first applanation (SP-A1) (P < 0.001) compared with normal controls. In contrast, OI group showed lower CBI (P < 0.001), lower TBI (P < 0.001), higher CBiF (P < 0.001), and higher SP-A1 (P = 0.020) than keratoconus group. Notably, the stress-strain index (SSI) was not significantly different between the OI and normal controls (P = 1.000), whereas keratoconus showed the lowest SSI compared with OI group (P = 0.025) and normal controls (P < 0.001).

CONCLUSIONS

Although the corneal structures of OI patients are less stable and easier to deform as compared to those of the control group, there is no significant difference in material stiffness observed between the OI and normal controls. In contrast, the corneas of keratoconus showed not only lower structural stability and higher deformability but also lower material stiffness compared with those of OI cornea and normal controls.

TRANSLATIONAL RELEVANCE: The biomechanical alterations are different between OI corneas and keratoconus.

Для цитирования: Chou Chien-Chih, Shih Po-Jen, Jou Tzuu-Shuh, Hsu Min-Yen, Chen Jun-Peng, Hsu Rai-Hseng, Lee Ni-Chung, Chien Yin-Hsiu, Hwu Wuh-Liang, Wang I-Jong. Corneal Biomechanical Characteristics in Osteogenesis Imperfecta With Collagen Defect.. Translational vision science & technology. 2023. DOI: 10.1167/tvst.12.1.14.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.