Persistence of Legionella pneumophila in a hospital's water system: a 13-year survey.
Аннотация
OBJECTIVE
To describe the molecular epidemiology of Legionella pneumophila infections in the University of Iowa Hospitals and Clinics (UIHC).
DESIGN
Molecular epidemiological study using pulsed-field gel electrophoresis (PFGE).
SETTING
A large university teaching hospital. ISOLATES: All surviving isolates obtained from culture-proven nosocomial L. pneumophila infections and all surviving isolates obtained from the University of Iowa Hospital and Clinics' water supply between 1981 and 1993.
RESULTS
Thirty-three isolates from culture-proven nosocomial cases of L. pneumophila pneumonia were available for typing. PFGE of genomic DNA from the clinical isolates identified six different strains. However, only strain C (16 cases) and strain D (13 cases) caused more than 1 case. Strain C caused clusters of nosocomial infection in 1981, 1986, and 1993 and also caused 4 sporadic cases. Strain D caused a cluster in 1987 and 1988 plus 4 sporadic cases. Of the six strains causing clinical infections, only strains C and D were identified in water samples. PFGE identified three strains in the water supply, of which strains C and D caused clinical disease and also persisted in the water supply during most of the study period.
CONCLUSION
Specific strains of L. pneumophila can colonize hospital water supplies and cause nosocomial infections over long periods of time.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.