MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s44161-025-00681-7

Медицинская библиотека · Nature cardiovascular research · 2025

The thrombin receptor PAR1 orchestrates changes in lymphatic endothelial cell junction morphology to augment lymphatic drainage during lung injury.

Chou Chou, Paredes Camila Ceballos, Summers Barbara, Palmer-Johnson Jade, Trivedi Anjali, Bhagwani Aneel, Hansen Kasper B, Kristensen Anders S, Gyoneva Stefka, Swanger Sharon A, Traynelis Stephen F, Reed Hasina Outtz

СтатьяПеревод в очереди

Аннотация

The lung lymphatic vasculature is capable of remarkable increases in lymphatic drainage in settings of inflammation and edema; however, the mechanisms driving this are not clear. Here we show that lung injury transforms the configuration of lung lymphatic endothelial cell junctions from a continuous 'zippered' configuration to a discontinuous and permeable 'button' configuration. Despite similarity to the junctional changes often seen in leaky and dysfunctional blood vessels, we find that the shift to button junctions in the lymphatic vasculature has an opposite effect, resulting in augmented lung lymphatic drainage. Mechanistically, we demonstrate that lung lymphatic button junction formation in models of lung injury is dependent on the thrombin receptor protease-activated receptor 1, a known mediator of blood vessel permeability. These results uncover a previously unknown role for the thrombin receptor protease-activated receptor 1 in the lymphatic vasculature that promotes a similar change in junction morphology as seen in blood vessels, but with a disparate effect on lymphatic function.

Для цитирования: Chou Chou, Paredes Camila Ceballos, Summers Barbara, Palmer-Johnson Jade, Trivedi Anjali, Bhagwani Aneel, Hansen Kasper B, Kristensen Anders S, Gyoneva Stefka, Swanger Sharon A, Traynelis Stephen F, Reed Hasina Outtz. The thrombin receptor PAR1 orchestrates changes in lymphatic endothelial cell junction morphology to augment lymphatic drainage during lung injury.. Nature cardiovascular research. 2025. DOI: 10.1038/s44161-025-00681-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.