MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00464-019-07228-5

Медицинская библиотека · Surgical endoscopy · 2019

Efficacy of a modified double-guidewire technique using an uneven double lumen cannula (uneven method) in patients with surgically altered gastrointestinal anatomy (with video).

Takenaka Mamoru, Minaga Kosuke, Kamata Ken, Yamao Kentaro, Yoshikawa Tomoe, Ishikawa Rei, Okamoto Ayana, Yamazaki Tomohiro, Nakai Atsushi, Omoto Shunsuke, Komeda Yoriaki, Sakurai Toshiharu, Watanabe Tomohiro, Nishida Naoshi, Chiba Yasutaka, Kwon Chang-Il, Jeong Seok, Lee Tae Hoon, Kudo Masatoshi

Оценочное исследованиеСтатьяVideo-Audio MediaПеревод в очереди

Аннотация

BACKGROUND

Balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography (BE-ERCP) has been reported to be effective for patients with surgically altered gastrointestinal anatomy. However, selective biliary cannulation remains difficult in BE-ERCP. We examined the usefulness of a modified double-guidewire technique using an uneven double lumen cannula (the uneven method) for BE-ERCP in patients with surgically altered gastrointestinal anatomy.

METHODS

To clarify the usefulness of the uneven method for selective biliary cannulation in BE-ERCP in comparison to the pancreatic guidewire (PGW) method, 40 patients with surgically altered gastrointestinal anatomy who underwent BE-ERCP with successful placement of a guidewire in the pancreatic duct were evaluated. The uneven method was used in 18 cases (uneven group) and the PGW method was used in the remaining 22 cases (PGW group).

RESULTS

The technical success rate of biliary cannulation was higher in the uneven group than in the PGW group (83.3 vs. 59.0%; P = 0.165). In addition, the time to biliary cannulation were significantly shorter in the uneven group than in the PGW group (6 vs. 18 min; P = 0.004; respectively). In the PGW group, post-ERCP pancreatitis (PEP) occurred in 3 of 22 cases (13.6%). No adverse events, including PEP, occurred in the uneven group.

CONCLUSIONS

The uneven method may be a useful option of selective biliary cannulation in BE-ERCP for the patients with surgically altered gastrointestinal anatomy.

Для цитирования: Takenaka Mamoru, Minaga Kosuke, Kamata Ken, Yamao Kentaro, Yoshikawa Tomoe, Ishikawa Rei, Okamoto Ayana, Yamazaki Tomohiro, Nakai Atsushi, Omoto Shunsuke, Komeda Yoriaki, Sakurai Toshiharu, Watanabe Tomohiro, Nishida Naoshi, Chiba Yasutaka, Kwon Chang-Il, Jeong Seok, Lee Tae Hoon, Kudo Masatoshi. Efficacy of a modified double-guidewire technique using an uneven double lumen cannula (uneven method) in patients with surgically altered gastrointestinal anatomy (with video).. Surgical endoscopy. 2019. DOI: 10.1007/s00464-019-07228-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.