MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/embc46164.2021.9629577

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2021

Pre-implant Heart Activity Differs in Responders and Non-responders to Vagal Nerve Stimulation Therapy in Epileptic Patients.

Plesinger F, Halamek J, Chladek J, Jurak P, Ivora A, Dolezalova I, Koritakova E, Jurkova T, Chrastina J, Brazdil M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Vagal Nerve Stimulation (VNS) is used to treat patients with pharmacoresistant epilepsy. However, generally accepted tools to predict VNS response do not exist. Here we examined two heart activity measures - mean RR and pNN50 and their complex behavior during activation in pre-implant measurements. The ECG recordings of 73 patients (38 responders, 36 non-responders) were examined in a 30-sec floating window before (120 sec), during (2x120 sec), and after (120 sec) the hyperventilation by nose and mouth. The VNS response differentiation by pNN50 was significant (min p=0.01) in the hyperventilation by a nose with a noticeable descendant trend in nominal values. The mean RR was significant (p=0.01) in the rest after the hyperventilation by mouth but after an approximately 40-sec delay.Clinical Relevance- Our study shows that pNN50 and mean RR can be used to distinguish between VNS responders and non-responders. However, details of dynamic behavior showed how this ability varies in tested measurement segments.

Для цитирования: Plesinger F, Halamek J, Chladek J, Jurak P, Ivora A, Dolezalova I, Koritakova E, Jurkova T, Chrastina J, Brazdil M. Pre-implant Heart Activity Differs in Responders and Non-responders to Vagal Nerve Stimulation Therapy in Epileptic Patients.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2021. DOI: 10.1109/embc46164.2021.9629577.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.