MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00380-020-01653-6

Медицинская библиотека · Heart and vessels · 2020

Risk factors for permanent pacemaker implantation in patients receiving a balloon-expandable transcatheter aortic valve prosthesis.

Droppa Michal, Rudolph Tanja K, Baan Jan, Nielsen Niels-Erik, Baumgartner Helmut, Vendrik Jeroen, Froehlich Maren, Borst Oliver, Wöhrle Jochen, Gawaz Meinrad, Potratz Paul, Hack Luis P, Mauri Victor, Baranowski Jacek, Bramlage Peter, Kurucova Jana, Thoenes Martin, Rottbauer Wolfgang, Geisler Tobias

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

Permanent pacemaker implantation (PPI) is a widely recognized complication associated with TAVI (incidence up to 20%). Smaller registries have identified several variables associated with PPI. The objective was to validate patient- and transcatheter aortic valve implantation (TAVI)-related procedural variables associated with PPI. We performed a retrospective analysis of patients from six European centers undergoing TAVI with the Edwards SAPIEN 3 prosthesis. Baseline variables and pre-procedural ECG characteristics and CT-scans were taken into account. Data for 1745 patients were collected; 191 (10.9%) required PPI after TAVI. The baseline variables pulmonary hypertension (OR 1.64; 95% CI 1.01-2.59), QRS duration > 117 ms (OR 2.58; 95% CI 1.73-3.84), right bundle branch block (RBBB; OR 5.14; 95% CI 3.39-7.72), left anterior hemi block (OR 1.92; 95% CI 1.19-3.02) and first-degree atrioventricular block (AVB, OR 1.63; 95%CI 1.05-2.46) were significantly associated with PPI. RBBB (OR 8.11; 95% CI 3.19-21.86) and first-degree AVB (OR 2.39; 95% CI 1.18-4.66) remained significantly associated in a multivariate analysis. Procedure-related variables included access site (TF; OR 1.97; 95% CI 1.07-4.05), implanted valve size (29 mm; OR 1.88; 95% CI 1.35-2.59), mean TAVI valve implantation depth below the annulus > 30% (OR 3.75; 95% CI 2.01-6.98). Patients receiving PPI had longer ICU stays and later discharges. Acute kidney injury stage 2/3 was more common in patients with PPI until discharge (15.2 vs. 3.1%; p = 0.007), but was not statistically significant thereafter. Further differences in outcomes at 30 days did not reach significance. The data will aid pre- and post-procedural patient management and prevent adverse long-term outcomes.Clinical Trial: NCT03497611.

Для цитирования: Droppa Michal, Rudolph Tanja K, Baan Jan, Nielsen Niels-Erik, Baumgartner Helmut, Vendrik Jeroen, Froehlich Maren, Borst Oliver, Wöhrle Jochen, Gawaz Meinrad, Potratz Paul, Hack Luis P, Mauri Victor, Baranowski Jacek, Bramlage Peter, Kurucova Jana, Thoenes Martin, Rottbauer Wolfgang, Geisler Tobias. Risk factors for permanent pacemaker implantation in patients receiving a balloon-expandable transcatheter aortic valve prosthesis.. Heart and vessels. 2020. DOI: 10.1007/s00380-020-01653-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.