MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1758573214536535

Медицинская библиотека · Shoulder & elbow · 2014

Open reduction and fixation of displaced lateral clavicle fractures using the Minimally Invasive Acromioclavicular Joint Reconstruction (MINAR®) technique: a case series review.

Kenyon Peter, Morgan Barnes William, Webb Mark, Ebreo Darren, Wheelton Andrew, Ravenscroft Matt John

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Lateral end of clavicle fractures can be a challenge, with a 20% to 30% non-union rate if treated non-operatively. Several operative options exist, each having their own merits and some having potential disadvantages. The Minimally Invasive Acromioclavicular Joint Reconstruction (MINAR®) (Storz, Tutlingen, Germany) set uses an Orthocord (Depuy Synthes Mitek, Leeds, UK) suture and two Flip Tacks (Storz) via a transclavicular-coracoid approach to reconstruct the coracoclavicular ligaments.

METHODS

Referrals were made to two senior surgeons at separate institutions regarding Robinson Type 3 fractures of the lateral end of the clavicle. All patients were treated with MINAR implant via a minimally invasive approach. Two-year follow-up was obtained using the Oxford Shoulder Score (OSS) and the Quick DASH (Disability of the Arm Shoulder and Hand) score.

RESULTS

Sixteen cases of acute fractures of the lateral end of the clavicle were included in this series. At final follow-up, the mean OSS was 44.75 (range 35 to 48) and the median Quick DASH score was 2.3 (range 0 to 35.9). Fifteen patients achieved bony union (one asymptomatic non-union) and there were no complications or re-operations.

CONCLUSIONS

The MINAR is reproducible and safe when treating lateral end of clavicle fractures. We consider that, over the short- to mid-term, it achieves results equivalent to those for other implants.

Для цитирования: Kenyon Peter, Morgan Barnes William, Webb Mark, Ebreo Darren, Wheelton Andrew, Ravenscroft Matt John. Open reduction and fixation of displaced lateral clavicle fractures using the Minimally Invasive Acromioclavicular Joint Reconstruction (MINAR®) technique: a case series review.. Shoulder & elbow. 2014. DOI: 10.1177/1758573214536535.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.