To determine the sensitivity, specificity, and diagnostic accuracy of diffusion-weighted MRI in localization of non-palpable undescended testes taking laparoscopic findings as the gold standard: A cross-sectional study from Pakistan.

Fazal Kamran, Hussain Shaiq, Khan Faheemullah, Ullah Irfan, Tahir Muhammad Junaid, Mehmood Qasim, Yousaf Zohaib

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Cryptorchidism, undescended testes, is a pathological condition that is due to failure of descent of testes in the scrotum. This study was aimed to determine the diagnostic accuracy of diffusion-weighted magnetic resonance imaging (DW-MRI) in localization of undescended testes taking laparoscopic findings as the gold standard.

METHODS

A cross-sectional study was conducted in the radiology department of a tertiary care hospital from September 27, 2018 to September 26, 2019. A total of 416 patients were included. Abdomen-pelvic and scrotal ultrasound were performed. Preoperative abdominal and pelvic DW-MRI was performed with a 1.5-T MRI system using a body coil. All study patients underwent laparoscopic exploration. Intra-abdominal atrophic testes were treated with laparoscopic orchiectomy and orchiectomy samples were taken for histopathologic examination. DW-MRI findings were correlated with laparoscopic findings. A 2 x 2 table was used to calculate the sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of DW-MRI taking laparoscopy as the gold standard.

RESULTS

The mean age was 17.08 ± 7.99 years and the mean BMI was 19.36 ± 4.96 kg/m2. In our study, 34.1% of cases were diagnosed as undescended testes localized by DWI-MRI and 51% of cases were diagnosed as undescended testes localized via laparoscopy. Sensitivity, specificity, PPV, NPV and accuracy were 65.1%, 98%, 97.2%, 73% and 81.3% respectively.

CONCLUSION

DW-MRI improves the detection of undescended testes. DW-MRI can be a recommended imaging tool to increase the preoperative diagnostic accuracy of MRI in localizing nonpalpable undescended testes.

Для цитирования: Fazal Kamran, Hussain Shaiq, Khan Faheemullah, Ullah Irfan, Tahir Muhammad Junaid, Mehmood Qasim, Yousaf Zohaib. To determine the sensitivity, specificity, and diagnostic accuracy of diffusion-weighted MRI in localization of non-palpable undescended testes taking laparoscopic findings as the gold standard: A cross-sectional study from Pakistan.. Annals of medicine and surgery (2012). 2021. DOI: 10.1016/j.amsu.2021.103161.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.