Natural history of anterior chest wall numbness after plating of clavicle fractures: educating patients.

Christensen Thomas J, Horwitz Daniel S, Kubiak Erik N

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

Improved patient outcomes after plating of displaced clavicle fractures have been demonstrated by recent clinical studies. Many of these patients, however, complain of anterior chest wall numbness after this procedure; we hypothesize that numbness likely persists long term for many patients, but without effect on shoulder function.

DESIGN

Prospective observational cohort.

SETTING

Level 1 trauma center.

PATIENTS/

PARTICIPANTS

Adult patients undergoing plating of a displaced middle third diaphyseal clavicle fracture.

INTERVENTION: Open reduction and internal fixation with superior clavicle plating.

MAIN OUTCOME MEASUREMENTS: The primary outcome is anterior chest wall numbness size (in square centimeters) and location as measured with a numbness transparency grid. Secondary outcomes include Visual Analog scale, Disabilities of the Arm, Shoulder, and Hand, and Constant scores 1 year postoperatively.

RESULTS

Twenty-five of 27 consecutive patients met inclusion/exclusion criteria, with 92% 1-year follow-up. Numbness at 2 weeks is very common, involving 83% of patients, with a mean area of 44 cm. Numbness at 1 year remains relatively common, involving 52% of patients, with a mean area of 15 cm (66% decrease in area from 2 weeks, P = 0.009). Numbness at 2 weeks predicted a 63% chance of continued 1-year numbness (37% resolved); Constant, Disabilities of the Arm, Shoulder, and Hand, and Visual Analog scale pain scores remained excellent in all patients at final follow-up, without correlation between numbness and outcome measures (r < 0.170).

CONCLUSIONS

Anterior chest wall numbness after open reduction internal fixation of displaced clavicle fractures is very common in the early postoperative period and may remain high 1 year postoperatively. Numbness 1 year after surgery is not associated with poor clinical outcome measures.

LEVEL OF EVIDENCE: Prognostic level IV. See instructions for authors for a complete description of levels of evidence.

Для цитирования: Christensen Thomas J, Horwitz Daniel S, Kubiak Erik N. Natural history of anterior chest wall numbness after plating of clavicle fractures: educating patients.. Journal of orthopaedic trauma. 2014. DOI: 10.1097/bot.0000000000000095.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.