MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10096-023-04681-y

Медицинская библиотека · European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2023

Multicenter interlaboratory study of routine systems for the susceptibility testing of temocillin using a challenge panel of multidrug-resistant strains.

Deckers Corentin, Bélik Florian, Denis Olivier, Montesinos Isabel, Bogaerts Pierre, Boelens Jerina, Brassinne Laetitia, Descy Julie, Desmet Stefanie, Gils Sarah, Lissoir Bénédicte, Magerman Koen, Matheeussen Veerle, Meex Cécile, Rodriguez Villalobos Hector, Van den Abeele Anne Marie, Vernelen Kris, Ceyssens Pieter-Jan, Huang Te-Din, Belgian National Antibiogram Committee

Многоцентровое исследованиеСтатьяПеревод в очереди

Аннотация

Accurate susceptibility result of temocillin (TMO) is important for treating infections caused by multidrug-resistant Enterobacterales. This multicenter study aimed to investigate the performance of routine temocillin testing assays against Enterobacterales challenging strains. Forty-seven selected clinical isolates were blindly analyzed by 12 Belgian laboratories using VITEK® 2 (n = 5) and BD Phoenix™ (n = 3) automated systems, ETEST® gradient strip (n = 3), and disk (3 brands) diffusion method (DD; n = 6) for temocillin susceptibility using standardized methodology. Results were interpreted using EUCAST 2023 criteria and compared to the broth microdilution (BMD; Sensititre™ panel) method used as gold standard. Methods' reproducibility was assessed by testing 3 reference strains in triplicate. A total of 702 organism-drug results were obtained against 33 TMO-susceptible and 14 TMO-resistant isolates. Excluding Proteae species (P. mirabilis and M. morganii), the essential agreement rates were excellent (91.5-100%) for all MIC-based methods. The highest category agreement was achieved by ETEST® (97.5%) followed by VITEK® 2 (93.2%), disk diffusion (91.6%), and BD Phoenix™ (88.5%). BD Phoenix™ and paper disk diffusion overcalled resistance (11.5% and 6.8% of major discrepancies, respectively), while ROSCO tablets diffusion and VITEK® 2 generated higher very major discrepancies (7.1% and 4.2% respectively). Inter-assay reproducibility was unsatisfactory using recommended E. coli ATCC 25922 strain but was excellent with E. coli ATCC 35218 and K. pneumoniae ATCC 700603 strains. This interlaboratory study suggests that routine testing methods provide accurate and reproducible TMO categorization results except for Proteae species.

Для цитирования: Deckers Corentin, Bélik Florian, Denis Olivier, Montesinos Isabel, Bogaerts Pierre, Boelens Jerina, Brassinne Laetitia, Descy Julie, Desmet Stefanie, Gils Sarah, Lissoir Bénédicte, Magerman Koen, Matheeussen Veerle, Meex Cécile, Rodriguez Villalobos Hector, Van den Abeele Anne Marie, Vernelen Kris, Ceyssens Pieter-Jan, Huang Te-Din, Belgian National Antibiogram Committee. Multicenter interlaboratory study of routine systems for the susceptibility testing of temocillin using a challenge panel of multidrug-resistant strains.. European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology. 2023. DOI: 10.1007/s10096-023-04681-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.