MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ihj.2017.07.020

Медицинская библиотека · Indian heart journal · 2017

Simplified percutaneous closure of patent foramen ovale and atrial septal defect with use of plain fluoroscopy: Single operator experience in 110 consecutive patients.

Manolis Antonis S, Koulouris Spyridon, Rouska Efthymia, Pyrros John

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Percutaneous closure of patent foramen ovale (PFO) and atrial septal defect (ASD) is routinely performed under general anesthesia or deep sedation and use of transesophageal (TEE) or intracardiac echocardiography, incurring longer duration and higher cost. We have used a simplified, economical, fluoroscopy-only guided approach with local anesthesia, and herein report our data.

METHODS

The study includes 112 procedures in 110 patients with PFO (n=75) or ASD (n=35), with use of an Amplatzer occluder, heparin and prophylactic antibiotics. Balloon sizing guided ASD-device selection. All patients received aspirin and clopidogrel for 6 months, when they all underwent TEE.

RESULTS

All PFOs but one (98.7%) and all (100%) ASDs were successfully closed with only one complication (local pseudoaneurysm). At the 6-month TEE, there was no residual shunt in PFO patients, but 2 ASD patients had residual shunts. During long-term (4.3-year) follow-up, no stroke recurrence in PFO patients, and no other problems were encountered. Among 54 patients suffering from migraine, symptom relief or resolution was reported by 45 (83.3%) patients.

CONCLUSION

Percutaneous placement of an Amplatzer occluder was safe and effective with use of local anesthesia and fluoroscopy alone. There were no recurrent strokes over >4 years. Migraine relief was reported by >80% of patients.

Для цитирования: Manolis Antonis S, Koulouris Spyridon, Rouska Efthymia, Pyrros John. Simplified percutaneous closure of patent foramen ovale and atrial septal defect with use of plain fluoroscopy: Single operator experience in 110 consecutive patients.. Indian heart journal. 2017. DOI: 10.1016/j.ihj.2017.07.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.