MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-015-2271-1

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2015

Arthroscopically assisted stabilization of displaced lateral clavicle fractures with coracoclavicular instability.

Kraus Natascha, Stein Verena, Gerhardt Christian, Scheibel Markus

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Lateral clavicle fractures associated with partial or complete injury of the coracoclavicular ligaments have traditionally been treated using a variety of open surgical techniques.

PURPOSE OF THE STUDY: The aim of this prospective study was the evaluation of the clinical and radiologic outcome of displaced lateral clavicular fractures with coracoclavicular instability treated in an arthroscopic single TightRope technique including an interfragmentary cerclage.

METHODS

From 2008 to 2010, 23 patients [8 women and 15 men; mean age 38 (24-63) years] who sustained a displaced lateral clavicular fracture type II according to Neer were included in this study. The follow-up consisted of a complete physical examination of the shoulder including range of motion, the constant score (CS), and the subjective shoulder value (SSV). The radiological follow-up included an anteroposterior stress view with 10 kg of axial load and bilateral axillary views to evaluate the coracoclavicular distance, the clavicular implant position, and healing of the fracture.

RESULTS

After a mean follow-up of 23.0 (13-38) months, 20 patients (7 women and 13 men; mean age 38.3 (24-53) years) were available for follow-up. On average, patients achieved 95.1 (60-100) % in the SSV, 88.7 (64-99; contralateral side 91.8 points; p > 0.05) points in the CS. Radiologically, 18 of 20 patients (90 %) displayed a bony healing of the fracture. The average coracoclavicular distance of 11.2 (6-14) mm did not differ significantly from the healthy side [9.9 (8-14) mm]. In six cases (30 %), coracoclavicular ossifications appeared. Two of 20 patients had concomitant glenohumeral lesions (10 %). Two patients had secondary surgery [implant removal (N = 1 local implant irritation); plate osteosynthesis (N = 1 early loss of reduction)].

CONCLUSION

The arthroscopic-assisted and image intensifier-controlled closed reduction and single TightRope fixation with interfragmentary cerclage of displaced lateral clavicular fractures with coracoclavicular instability yields excellent clinical results and is able to recreate stability of the clavicle.

Для цитирования: Kraus Natascha, Stein Verena, Gerhardt Christian, Scheibel Markus. Arthroscopically assisted stabilization of displaced lateral clavicle fractures with coracoclavicular instability.. Archives of orthopaedic and trauma surgery. 2015. DOI: 10.1007/s00402-015-2271-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.