MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/rcm.9754

Медицинская библиотека · Rapid communications in mass spectrometry : RCM · 2024

Simultaneous quantification of six proteins related to liver injury using nano liquid chromatography-tandem mass spectrometry.

Cai Siyu, Su Yuan, Shi Mengtian, Wang Dandan, Chen David Da Yong, Yan Binjun

СтатьяПеревод в очереди

Аннотация

RATIONALE: In clinical diagnosis of liver injury, which is an important health concern, serum aminotransferase assays have been the go-to method used worldwide. However, the measurement of serum enzyme activity has limitations, including inadequate disease specificity and enzyme specificity.

METHODS

With the high selectivity and specificity provided by nano liquid chromatography-tandem mass spectrometry (LC/MS/MS), this work describes a method for the simultaneous determination of six proteins in liver that can be potentially used as biomarkers for liver injury: glutamic-pyruvic transaminase 1 (GPT1), glutamic oxaloacetic transaminase 1 (GOT1), methionine adenosyl transferase 1A (MAT1A), glutathione peroxidase 1 (GPX1), cytokeratin 18 (KRT18) and apolipoprotein E (APOE).

RESULTS

In validation, the method was shown to have good selectivity and sensitivity (limits of detection at pg/mL level). The analytical method revealed that, compared with normal mice, in carbon tetrachloride-induced acute liver injury mice, liver MAT1A and GPX1 were significantly lower (p < 0.01 and p < 0.05, respectively), KRT18 was significantly higher (p < 0.05) and APOE and GPT1 were marginally significantly lower (p between 0.05 and 0.1). This is the first work reporting the absolute contents of GPT1, GOT1, MAT1A, GPX1 and KRT18 proteins based on LC/MS.

CONCLUSIONS

The proposed method provides a basis for establishing more specific diagnostic indicators of liver injury.

Для цитирования: Cai Siyu, Su Yuan, Shi Mengtian, Wang Dandan, Chen David Da Yong, Yan Binjun. Simultaneous quantification of six proteins related to liver injury using nano liquid chromatography-tandem mass spectrometry.. Rapid communications in mass spectrometry : RCM. 2024. DOI: 10.1002/rcm.9754.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.