MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.avsg.2018.06.029

Медицинская библиотека · Annals of vascular surgery · 2018

Outcomes of a Polytetrafluoroethylene Hybrid Vascular Graft with Preloaded Nitinol Stent at the Venous Outflow for Dialysis Vascular Access.

Habibollahi Peiman, Mantell Mark P, Rosenberry Trish, Leeser David B, Clark Timothy W I

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

To evaluate outcomes and patency of arteriovenous grafts (AVGs) created using Gore hybrid vascular grafts in hemodialysis patients with limited venous outflow or challenging anatomy.

MATERIALS AND

METHODS

A retrospective review was performed in two academic centers of all patients between July 2013 and December 2016 who underwent surgical AVG creation using a Gore hybrid vascular graft in a brachial artery to axillary configuration. Patient characteristics and comorbidities as well as graft patency, function, and subsequent need for percutaneous interventions were recorded.

RESULTS

Forty-six patients including 30 females (65.2%) and 16 males (34.8%) with a mean age of 63 ± 13 years were identified. The most common indications for a hybrid vascular graft were limited surgical accessibility and/or revision of existing AVG due to severe stenotic lesions at the venous outflow in 33 patients (72%). One-year primary unassisted and assisted patency rates were 44 ± 8% and 54 ± 8%, respectively, compared with 1-year secondary patency rate of 66 ± 8%. The rate of percutaneous interventions to maintain graft function and patency was approximately one intervention per graft per year.

CONCLUSIONS

Access created with the hybrid vascular graft in a brachial-axillary (brachial artery to axillary vein) configuration is an acceptable option for patients with limited venous outflow reserve and challenging anatomy. Twelve-month primary and secondary patency rates and need for percutaneous interventions were comparable to traditional AVGs.

Для цитирования: Habibollahi Peiman, Mantell Mark P, Rosenberry Trish, Leeser David B, Clark Timothy W I. Outcomes of a Polytetrafluoroethylene Hybrid Vascular Graft with Preloaded Nitinol Stent at the Venous Outflow for Dialysis Vascular Access.. Annals of vascular surgery. 2018. DOI: 10.1016/j.avsg.2018.06.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.