MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12874-024-02248-9

Медицинская библиотека · BMC medical research methodology · 2024

The performance of a Bayesian value-based sequential clinical trial design in the presence of an equivocal cost-effectiveness signal: evidence from the HERO trial.

Welch Charlie, Forster Martin, Ronaldson Sarah, Keding Ada, Corbacho-Martín Belen, Tharmanathan Puvan

СтатьяПеревод в очереди

Аннотация

BACKGROUND

There is increasing interest in the capacity of adaptive designs to improve the efficiency of clinical trials. However, relatively little work has investigated how economic considerations - including the costs of the trial - might inform the design and conduct of adaptive clinical trials.

METHODS

We apply a recently published Bayesian model of a value-based sequential clinical trial to data from the 'Hydroxychloroquine Effectiveness in Reducing symptoms of hand Osteoarthritis' (HERO) trial. Using parameters estimated from the trial data, including the cost of running the trial, and using multiple imputation to estimate the accumulating cost-effectiveness signal in the presence of missing data, we assess when the trial would have stopped had the value-based model been used. We used re-sampling methods to compare the design's operating characteristics with those of a conventional fixed length design.

RESULTS

In contrast to the findings of the only other published retrospective application of this model, the equivocal nature of the cost-effectiveness signal from the HERO trial means that the design would have stopped the trial close to, or at, its maximum planned sample size, with limited additional value delivered via savings in research expenditure.

CONCLUSION

Evidence from the two retrospective applications of this design suggests that, when the cost-effectiveness signal in a clinical trial is unambiguous, the Bayesian value-adaptive design can stop the trial before it reaches its maximum sample size, potentially saving research costs when compared with the alternative fixed sample size design. However, when the cost-effectiveness signal is equivocal, the design is expected to run to, or close to, the maximum sample size and deliver limited savings in research costs.

Для цитирования: Welch Charlie, Forster Martin, Ronaldson Sarah, Keding Ada, Corbacho-Martín Belen, Tharmanathan Puvan. The performance of a Bayesian value-based sequential clinical trial design in the presence of an equivocal cost-effectiveness signal: evidence from the HERO trial.. BMC medical research methodology. 2024. DOI: 10.1186/s12874-024-02248-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.