BACKGROUND

The fixation of inferior pole fractures of the patella (IPFPs) is still a great challenge for surgeons.

MATERIALS AND

METHODS

We introduced a new fixation method for IPFP fixation, that is, separate vertical wiring plus bilateral anchor girdle suturing fixation (SVW-BSAG). Three finite element models including the anterior tension band wiring (ATBW) model, separate vertical wiring (SVW) model and SVW-BSAG model, were built to evaluate the fixation strength of different fixation methods. A total of 41 consecutive patients with IPFP injury were enrolled in this retrospective study, including 23 patients in the ATBW group and 18 patients in the SVW-BSAG group. The operation time, radiation exposure, full weight-bearing time, Bostman score, extension lag versus contralateral healthy leg, Insall-Salvati ratio, and radiograph outcomes were employed to assess and compare the ATBW group and SVW-BSAG group.

RESULTS

The finite element analysis confirmed that the SVW-BSAG fixation method was as reliable as the ATBW fixation method in terms of fixed strength. Through retrospective analysis, we found that there was no significant difference between the SVW-BSAG and ATBW groups in age, sex, BMI, fracture side, fracture type, or follow-up time. There were no significant differences between the two groups in the Insall-Salvati ratio, 6-month Bostman score, and fixation failure. Compared with the ATBW group, the SVW-BSAG group showed advantages in intraoperative radiation exposure, full weight-bearing time, and extension lag versus the contralateral healthy leg.

CONCLUSION

The finite element analysis and clinical results showed that SVW-BSAG fixation methods are a reliable and valuable for IPFP treatment.

Для цитирования: Li Shi-Jie, Tiwari Shashi Ranjan, Chang Shi-Min, Du Shou-Chao, Zhang Ying-Qi. Separate vertical wiring plus bilateral anchor girdle suturing fixation for the fractures of the inferior pole of the patella.. Journal of orthopaedic surgery and research. 2023. DOI: 10.1186/s13018-023-03649-0.