MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_472_18

Медицинская библиотека · Indian journal of ophthalmology · 2018

Low-cost three-dimensional printed orbital template-assisted patient-specific implants for the correction of spherical orbital implant migration.

Dave Tarjani Vivek, Tiple Sweety, Vempati Sandeep, Palo Mansha, Ali Mohammad Javed, Kaliki Swathi, Naik Milind N

Клинический случайСтатьяПеревод в очереди

Аннотация

PURPOSE: To describe the outcomes of a patient-specific implant (PSI), fabricated using a three-dimensional (3D) printed orbital template and placed in the basin of the inferior orbital fissure to correct inferotemporally migrated spherical orbital implant.

METHODS

This is a single-center, prospective, consecutive, interventional, case series of six patients, with non-porous, spherical, orbital implant migration that underwent implant recentration surgically with a novel technique. Migration was subclassified either as decentration that did not affect the prosthetic retention or as displacement that affected the prosthetic retention in the eye socket. Only implant displacements were treated. The primary outcome measure was centration of the implant clinically and radiologically, with ability to retain the prosthesis.

RESULTS

At a mean follow-up of 21 months, all six orbital spherical implants remained centered. There were no cases of extrusion, exposure, or migration of either implants. There were no cases of PSI displacement. Additional procedures to optimize the aesthetic outcome of the customized ocular prosthesis (COP) required were simultaneous fornix formation suture in three patients, subsequent fornix formation with mucus membrane graft in two patients, and levator resection and sulcus hyaluronic acid gel injection in one patient each. The mean PSI implant weight was 2.66 ± 0.53 g. The mean COP weight was 2.2 ± 0.88 g postoperatively. The median patient satisfaction with the procedure was 9 on 10.

CONCLUSION

A 3D printing-assisted PSI placed in the basin of the inferior orbital fissure allows recentration of the migrated implant over a follow-up of 21 months without complications.

Для цитирования: Dave Tarjani Vivek, Tiple Sweety, Vempati Sandeep, Palo Mansha, Ali Mohammad Javed, Kaliki Swathi, Naik Milind N. Low-cost three-dimensional printed orbital template-assisted patient-specific implants for the correction of spherical orbital implant migration.. Indian journal of ophthalmology. 2018. DOI: 10.4103/ijo.ijo_472_18.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.