OBJECTIVE

Molecular testing determines D antigen status when abnormal serologic results are observed. Molecular testing is routinely batched, resulting in longer turnaround time for abnormal D status resolution. During the interim, obstetric patients with questionable/uninterpretable and weak D typing results by serology, per the immunohematology reference laboratory (IRL) policy, will receive RhD negative blood. This study aimed to determine whether serology results achieved a concordance.

METHODS

Six hospitals provided samples to the IRL (first IRL) for RhD status by DNA. De-identified samples were sent for serology RhD (second IRL). A concordance of ≥80% was acceptable.

RESULTS

Forty-nine samples were evaluated. Results were concordant (65.3% [32/49]) and discordant (34.7% [17/49]). This is significantly lower than clinically acceptable 80% (z = 2.57, P < .05). The turnaround-time was 3.0 hours for serology and 4.4 days for molecular evaluation.

CONCLUSION

Due to a low concordance, serology could not be used in place of molecular testing.

Для цитирования: Gammon Richard R, Conceicao Michelle, Benitez Nancy, Bright Frieda, Counts Kelley, Resto Claribel, Rexer Karl. Comparison of RhD Typing Results by Serology and Molecular Methods.. Laboratory medicine. 2023. DOI: 10.1093/labmed/lmac097.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.