MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circinterventions.114.002207

Медицинская библиотека · Circulation. Cardiovascular interventions · 2015

Assessment of Fractional Flow Reserve in Patients With Recent Non-ST-Segment-Elevation Myocardial Infarction: Comparative Study With 3-T Stress Perfusion Cardiac Magnetic Resonance Imaging.

Layland Jamie, Rauhalammi Samuli, Watkins Stuart, Ahmed Nadeem, McClure John, Lee Matthew M Y, Carrick David, O'Donnell Anna, Sood Arvind, Petrie Mark C, May Vannesa Teng Yue, Eteiba Hany, Lindsay Mitchell, McEntegart Margaret, Oldroyd Keith G, Radjenovic Aleksandra, Berry Colin

Клиническое исследованиеСравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The use of fractional flow reserve (FFR) in acute coronary syndromes is controversial. The British Heart Foundation Fractional Flow Reserve Versus Angiography in Guiding Management to Optimize Outcomes in Non-ST-Elevation Myocardial Infarction (FAMOUS-NSTEMI) study (NCT01764334) has recently demonstrated the safety and feasibility of FFR measurement in patients with non-ST-segment-elevation myocardial infarction. We report the findings of the cardiac magnetic resonance (CMR) substudy to assess the diagnostic accuracy of FFR compared with 3.0-T stress CMR perfusion.

METHODS AND

RESULTS

One hundred six patients with non-ST-segment-elevation myocardial infarction who had been referred for early invasive management were included from 2 centers. FFR was measured in all major patent epicardial coronary arteries with a visual stenosis estimated at ≥30%, and if percutaneous coronary intervention was performed, an FFR assessment was repeated. Myocardial perfusion was assessed with stress perfusion CMR at 3 T. The mean age was 56.7±9.8 years; 82.6% were men. Mean time from FFR evaluation to CMR was 6.1±3.1 days. The mean±SD left ventricular ejection fraction was 58.2±9.1%. Mean infarct size was 5.4±7.1%, and mean troponin concentration was 5.2±9.2 μg/L. There were 34 fixed and 160 inducible perfusion defects. There was a negative correlation between the number of segments with a perfusion abnormality and FFR (r=-0.77; P<0.0001). The overall sensitivity, specificity, positive predictive value, and negative predictive value for an FFR of ≤0.8 were 91.4%, 92.2%, 76%, and 97%, respectively. Diagnostic accuracy was 92%. The positive and negative predictive values of FFR for flow-limiting coronary artery disease (FFR≤0.8) in patients with non-ST-segment-elevation myocardial infarction (n=21) who underwent perfusion CMR before invasive angiography were 92% and 93%, respectively. Receiver operating characteristic analysis indicated that the optimal cutoff value of FFR for demonstrating reversible ischemia on CMR was ≤0.805 (area under the receiver operating characteristic curve, 0.94 [0.9-0.99]; P<0.0001).

CONCLUSIONS

FFR in patients with recent non-ST-segment-elevation myocardial infarction showed high concordance with myocardial perfusion in matched territories as revealed by 3.0-T stress perfusion CMR.

CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02073422.

Для цитирования: Layland Jamie, Rauhalammi Samuli, Watkins Stuart, Ahmed Nadeem, McClure John, Lee Matthew M Y, Carrick David, O'Donnell Anna, Sood Arvind, Petrie Mark C, May Vannesa Teng Yue, Eteiba Hany, Lindsay Mitchell, McEntegart Margaret, Oldroyd Keith G, Radjenovic Aleksandra, Berry Colin. Assessment of Fractional Flow Reserve in Patients With Recent Non-ST-Segment-Elevation Myocardial Infarction: Comparative Study With 3-T Stress Perfusion Cardiac Magnetic Resonance Imaging.. Circulation. Cardiovascular interventions. 2015. DOI: 10.1161/circinterventions.114.002207.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.