[Diagnosis of Legionella pneumonia by detection of antigenuria using an enzyme immunoassay with 6 antibody specificities].
Аннотация
In patients with microbiologically and clinically suspected Legionella caused pneumonia antigenuria was investigated by means of a direct two-site binding assay (ELISA) with polyclonal antibodies against Legionella (L.) pneumonia serogroup 1, 2, 3, 5 and 6 and L. micdadei. By application of antibodies only against L. pneumonia serogroup 1 antigenuria was found in 27 of 66 patients (= 41%). The expanding of the used specificities of antibodies in 47 out of this cases resulted in an increase of positive urinary antigen findings from 38% to 55%. Possibilities and limits of the detection of antigenuria with regard to efficient and rapid diagnostics of legionellosis are discussed.