OBJECTIVE

Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a method of gaining proximal control of noncompressible torso hemorrhage (NCTH). Catheter placement is traditionally confirmed with fluoroscopy, but few studies have evaluated whether ultrasound (US) can be used.

METHODS

Using a pressurized human cadaver model, a certified REBOA placer was shown one of four randomized cards that instructed them to place the REBOA either correctly or incorrectly in Zone 1 (the distal thoracic aorta extending from the celiac artery to the left subclavian artery) or Zone 3 (in the distal abdominal aorta, from the aortic bifurcation to the lowest renal artery). Once the REBOA was placed, 10 US-trained locators were asked to confirm balloon placement via US. The participants were given 3 minutes to determine whether the catheter had been correctly placed, repeating this 20 times on two cadavers.

RESULTS

Overall, US exhibited an average sensitivity of 83%, specificity of 76%, and accuracy of 80%. For Zone 1, US showed a sensitivity of 78% and specificity of 83%, and for Zone 3, a sensitivity of 88% and specificity of 76%. In addition, US exhibited a likelihood positive ratio (LR+) of 3.73 and a likelihood negative ratio (LR-) of 0.22 for either position, with similar numbers for Zone 1 (+4.57, -0.26) and Zone 3 (+3.16, -0.16).

CONCLUSION

Ultrasound could prove to be a useful tool for confirming placement of a REBOA catheter, especially in austere environments.

Для цитирования: Lopachin Tyler, Treager Christopher D, Sulava Eric F, Stuart Sean M, Bohan Megan L, Boboc Michael, Fernandez Pravina, Bianchi William D, McGowan Andrew J, Friedrich Emily E. Ultrasound Localization of Resuscitative Endovascular Balloon Occlusion of the Aorta in a Human Cadaver Model.. Journal of special operations medicine : a peer reviewed journal for SOF medical professionals. 2023. DOI: 10.55460/8mdd-by4i.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.