MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10895-022-02962-x

Медицинская библиотека · Journal of fluorescence · 2022

Biocompatible Carbon Dot Decorated α-FeOOH Nanohybrid for an Effective Fluorometric Sensing of Cr (VI) in Wastewater and Living Cells.

Ghosh Bidisha, Roy Shubham, Bardhan Souravi, Mondal Dhananjoy, Saha Ishita, Ghosh Saheli, Basu Ruma, Karmakar Parimal, Das Kaustuv, Das Sukhen

СтатьяПеревод в очереди

Аннотация

This article reports the fluorometric detection of toxic hexavalent chromium Cr (VI)) in wastewater and Cr (VI) contaminated living cells using in-situ grown carbon quantum dots into the goethite (α-FeOOH) nano-matrix. The synthesized nano-hybrid shows enormous potential in determining the chromium contamination levels in various types of water samples. This selective fluorometric probe is enormously sensitive (LOD 81 nM) toward hexavalent chromium, which makes it a dedicated chromium sensor. Moreover, the sensing mechanism has been assessed using Stern-Volmer's equation and fluorescence lifetime experiments showing the simultaneous occurrence of photoinduced electron transfer and the inner filter effect. This chromium sensor has also been employed to assess the contamination level in real-life industrial wastewater. The performance of this probe in a real-life wastewater sample is quite commendable. Further, this biocompatible fluorometric probe has been used to demonstrate the in-vitro sensing of Cr (VI) in HeLa cells. The rapid detection mechanism of hexavalent chromium in living cells has been validated using theoretical docking simulations. Henceforth, this fluorometric sensor material could open new avenues not only in wastewater monitoring but also in biomedical applications.

Для цитирования: Ghosh Bidisha, Roy Shubham, Bardhan Souravi, Mondal Dhananjoy, Saha Ishita, Ghosh Saheli, Basu Ruma, Karmakar Parimal, Das Kaustuv, Das Sukhen. Biocompatible Carbon Dot Decorated α-FeOOH Nanohybrid for an Effective Fluorometric Sensing of Cr (VI) in Wastewater and Living Cells.. Journal of fluorescence. 2022. DOI: 10.1007/s10895-022-02962-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.