MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2004.05.056

Медицинская библиотека · Journal of cataract and refractive surgery · 2005

Artisan iris-claw phakic intraocular lens followed by laser in situ keratomileusis for high hyperopia.

Muñoz Gonzalo, Alió Jorge L, Montés-Micó Robert, Albarrán-Diego César, Belda José I

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after Artisan phakic intraocular lens (IOL) implantation followed by laser in situ keratomileusis (LASIK) for the correction of high hyperopia.

SETTING

Instituto Oftalmólogico de Alicante, Alicante, Spain.

METHODS

This prospective trial included 39 eyes with a mean preoperative spherical equivalent (SE) of 7.39 diopters (D) +/- 1.30 (SD) and a cylinder between 0 and -4.25 D. The Artisan iris-fixated phakic IOL (Ophtec) for hyperopia was implanted, and LASIK was performed 6 to 8 months later. The best corrected visual acuity (BCVA), uncorrected visual acuity (UCVA), refraction, endothelial cell loss (ECL), endothelium morphologic analysis, and patient satisfaction were recorded. The minimum follow-up was 12 months.

RESULTS

At 1 year, 37 eyes (94.9%) were within +/-1.00 D of emmetropia and 31 eyes (79.5%) were within +/-0.50 D. Thirty-five eyes (89.7%) achieved a UCVA of 0.5 or better. There was a statistically significant decrease in BCVA after phakic IOL implantation, but this effect was corrected after LASIK. Nine eyes (23.1%) lost 1 line of BCVA; 7 eyes (17.9%) gained at least 1 line. One eye (2.6%) showed a change in SE greater than 1.0 D over the follow-up period. The mean ECL was 10.9%, but morphologic analysis suggested no additional damage caused by LASIK over that produced by phakic IOL surgery. Overall patient satisfaction was high.

CONCLUSIONS

The combination of Artisan phakic IOL implantation and LASIK safely, predictably, and effectively reduced high hyperopia. A loss of 1 line of BCVA should be expected in about one third of eyes implanted with this IOL. Halos and glare at night remain a potential problem.

Для цитирования: Muñoz Gonzalo, Alió Jorge L, Montés-Micó Robert, Albarrán-Diego César, Belda José I. Artisan iris-claw phakic intraocular lens followed by laser in situ keratomileusis for high hyperopia.. Journal of cataract and refractive surgery. 2005. DOI: 10.1016/j.jcrs.2004.05.056.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.