Аннотация

AIM: To explore the effect of embryo selection using the time-lapse monitoring (TLM) system compared with conventional morphological selection (CMS) on in vitro fertilization/intracytoplasmic sperm injection (IVF/ICSI) outcomes.

METHODS

We searched PubMed, Ovid-Embase, and The Cochrane Library for the following studies: At Comparison 1, embryo selection using TLM images in a TLM incubator based on morphology versus embryo selection using CMS in a conventional incubator based on morphology; at Comparison 2, embryo selection using TLM based on morphokinetics versus embryo selection using CMS based on morphology. The primary outcomes were the live birth rate (LBR), ongoing pregnancy rate (OPR), clinical pregnancy rate (CPR), and implantation rate (IR), and the secondary outcome was the miscarriage rate (MR).

RESULTS

A total of 14 randomized control trials (RCTs) were included. Both based on morphology, TLM incubators increased the IR (risk ratio [RR]: 1.10; 95% confidence interval [CI]: 1.01, 1.18; I2  = 0%, moderate-quality evidence) compared to conventional incubators. Low- to moderate-quality evidence suggests that TLM incubators did not improve LBR, OPR, CPR, and MR compared to conventional incubators. In addition, low- to moderate-quality evidence indicates that embryo selection using TLM based on morphokinetics did not improve LBR, OPR, CPR, IR, or MR compared to CMS based on morphology.

CONCLUSIONS

Low- to moderate-quality evidence suggests that neither TLM incubators nor embryo selection using TLM based on morphokinetics improved clinical outcomes (LBR, OPR, CPR, and MR) compared with CMS based on morphology. TLM is still an investigational procedure for IVF/ICSI practice.

Для цитирования: Jiang Yanbiao, Wang Liyan, Wang Sha, Shen Haofei, Wang Bin, Zheng Jianxiu, Yang Jinwei, Ma Bin, Zhang Xuehong. The effect of embryo selection using time-lapse monitoring on IVF/ICSI outcomes: A systematic review and meta-analysis.. The journal of obstetrics and gynaecology research. 2023. DOI: 10.1111/jog.15797.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.