DOI 10.1016/j.ejrad.2026.112859

Медицинская библиотека · European journal of radiology · 2026

Incremental value of deep learning denoising in low-dose coronary CT angiography in predominantly obese patients.

Osoria-Velasquez José, Byerly Kathryn, Vecsey-Nagy Milán, Shaheen Nicholas H, Hyska Sardi, Halfmann Moritz C, Bamberg Fabian, Rau Stephan, Emrich Tilman, Varga-Szemes Akos, Hagar Muhammad Taha

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine the added value of post-hoc convolutional neural network (CNN)-based denoising for low-radiation coronary CT angiography (CCTA).

METHODS

In this IRB-approved, post-hoc study, consecutive patients underwent clinically indicated CCTA on a third-generation dual-source CT scanner using a fast-pitch protocol and fully patient-tailored contrast injection. Images were reconstructed with a vascular kernel (Bv40) using iterative reconstruction (ADMIRE 4), with and without CNN-based denoising. Two readers assessed signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), attenuation, and subjective image quality across coronary segments using a 4-point scale. Linear mixed-effects models evaluated the relationship between body-mass index (BMI) and denoising efficiency.

RESULTS

Fifty-six participants (mean age 51.7 ± 12.8 years; 57.1% women), including 35 obese individuals (62.5%, BMI ≥ 30.0 kg/m2), were analyzed. The dose-length product was 77.15 [50.10-133.38] mGy·cm. CNN-denoising reduced image noise (35.1 ± 7.8 vs 21.0 ± 4.7 HU, p < 0.001) and improved SNR (12.0 ± 3.3 vs 22.0 ± 5.7, p < 0.001) and CNR (11.0 ± 3.0 vs 19.0 ± 5.2, p < 0.001), with stable attenuation (all p > 0.1). Subjective quality improved (2 [2,3] vs 3 [2,3], p < 0.001). Poor-quality vessels decreased from 23/156 (14.7%) to 14/156 (9.0%), and good-to-excellent quality increased from 82/156 (52.6%) to 117/156 (75.0%). Mixed-effects modeling showed 31% noise reduction (-13.9 HU, p < 0.001) and SNR (+8.5, p < 0.001) and CNR (+7.4, p < 0.001) gains, irrespective of BMI (p > 0.46).

CONCLUSION

CNN-based denoising improved objective and subjective image quality in low-dose CCTA independently of BMI in a predominantly obese cohort.

Для цитирования: Osoria-Velasquez José, Byerly Kathryn, Vecsey-Nagy Milán, Shaheen Nicholas H, Hyska Sardi, Halfmann Moritz C, Bamberg Fabian, Rau Stephan, Emrich Tilman, Varga-Szemes Akos, Hagar Muhammad Taha. Incremental value of deep learning denoising in low-dose coronary CT angiography in predominantly obese patients.. European journal of radiology. 2026. DOI: 10.1016/j.ejrad.2026.112859.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.