DOI 10.1016/j.healun.2026.02.1674

Медицинская библиотека · The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2026

Hybrid durable biventricular assist device implantation with Berlin Heart EXCOR pulsatile RVAD and a continuous flow LVAD.

Meyer Anna L, Bernhardt Alexander M, Garbade Jens, Eifert Sandra, Schmitto Jan D, Nozdrzykowski Michal, Assar Yousuf Al, Kremer Jamila, Dimitriu Alexander, Dashkevich Alexey, Schmack Bastian

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Biventricular failure or right ventricular failure (RVF) after continuous-flow left ventricular assist device (cf-LVAD) implantation is associated with high mortality. Durable right ventricular assist device (RVAD) options are limited, particularly for patients with critical cardiogenic shock or late-onset RVF. Use of right-sided cf-LVAD is costly, complex, and off-label. This study explores a hybrid VAD approach, combining a cf-LVAD and a Berlin Heart EXCOR pulsatile RVAD.

METHODS

This multicenter retrospective analysis included patients who received a cf-LVAD with an EXCOR RVAD at six centers in Germany between December 2017 and January 2024. Nineteen patients were analyzed. Baseline demographics, implantation strategy, duration of support, survival, and end-organ function were assessed.

RESULTS

Among the 19 patients, 73.7% were male, with a median age of 52 years (IQR 30.5-59.5). Seventeen (89.5%) patients initially presented in INTERMACS level 1 and 14 patients underwent stabilization with temporary mechanical circulatory support before durable VAD implantation resulting in a shift to INTERMACS level 3. Simultaneous LVAD and RVAD implantation occurred in 13 (68.4%) patients. Median hybrid support duration was 112 days (range 9 - 1363 days). One-year mortality was 21.1% overall and 14.3% in patients with simultaneous BIVAD implantation. Improved renal and hepatic function was observed, particularly in patients with simultaneous biventricular support.

CONCLUSION

Hybrid support using a cf-LVAD with an EXCOR RVAD is a feasible and effective strategy for patients with biventricular failure. This approach demonstrated favorable survival, especially with simultaneous implantation, and was associated with improved end-organ function.

Для цитирования: Meyer Anna L, Bernhardt Alexander M, Garbade Jens, Eifert Sandra, Schmitto Jan D, Nozdrzykowski Michal, Assar Yousuf Al, Kremer Jamila, Dimitriu Alexander, Dashkevich Alexey, Schmack Bastian. Hybrid durable biventricular assist device implantation with Berlin Heart EXCOR pulsatile RVAD and a continuous flow LVAD.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2026. DOI: 10.1016/j.healun.2026.02.1674.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.