Аннотация
Rationale: Moderate-severe obstructive sleep apnea (OSA) (apnea-hypopnea index [AHI], >15 events/h) disturbs sleep through frequent bouts of apnea and is associated with daytime sleepiness. However, many individuals without moderate-severe OSA (i.e., AHI <15 events/h) also report sleepiness.
Objectives
To test the hypothesis that sleepiness in the AHI <15 events/h group is a consequence of substantial flow limitation in the absence of overt reductions in airflow (i.e., apnea/hypopnea).
Methods
A total of 1,886 participants from the MESA sleep cohort were analyzed for frequency of flow limitation from polysomnogram-recorded nasal airflow signal. Excessive daytime sleepiness (EDS) was defined by an Epworth Sleepiness Scale score ⩾11. Covariate-adjusted logistic regression assessed the association between EDS (binary dependent variable) and frequency of flow limitation (continuous) in individuals with an AHI <15 events/h.
Results
A total of 772 individuals with an AHI <15 events/h were included in the primary analysis. Flow limitation was associated with EDS (odds ratio, 2.04; 95% confidence interval, 1.17-3.54; per 2-standard deviation increase in flow limitation frequency) after adjusting for age, sex, body mass index, race/ethnicity, and sleep duration. This effect size did not appreciably change after also adjusting for AHI.
Conclusions
In individuals with an AHI <15 events/h, increasing flow limitation frequency by 2 standard deviations is associated with a twofold increase in the risk of EDS. Future studies should investigate addressing flow limitation in low-AHI individuals as a potential mechanism for ameliorating sleepiness.