MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ndt/gfad149

Медицинская библиотека · Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 2023

Predictors of graft failure after first detection of de novo donor-specific HLA antibodies in kidney transplant recipients.

López Del Moral Covadonga, Wu Kaiyin, Naik Marcel, Osmanodja Bilgin, Akifova Aylin, Lachmann Nils, Stauch Diana, Hergovits Sabine, Choi Mira, Bachmann Friederike, Halleck Fabian, Schrezenmeier Eva, Schmidt Danilo, Budde Klemens

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

De novo donor-specific antibodies (dnDSAs) may cause antibody-mediated rejection and graft dysfunction. Little is known about the clinical course after first detection of dnDSAs during screening in asymptomatic patients. We aimed to assess the value of estimated glomerular filtration rate (eGFR) and proteinuria to predict graft failure in patients with dnDSAs and their potential utility as surrogate endpoints.

METHODS

All 400 kidney transplant recipients with dnDSAs at our centre (1 March 2000-31 May 2021) were included in this retrospective study. The dates of graft loss, rejection, doubling of creatinine, ≥30% eGFR decline, proteinuria ≥500 mg/g and ≥1000 mg/g were registered from the first dnDSA appearance.

RESULTS

During 8.3 years of follow-up, graft failure occurred in 33.3% of patients. Baseline eGFR and proteinuria correlated with 5-year graft loss (area under the receiver operating characteristics curve 0.75 and 0.80, P < .001). Creatinine doubled after a median of 2.8 years [interquartile range (IQR) 1.5-5.0] from dnDSA and the time from doubling creatinine to graft failure was 1.0 year (IQR 0.4-2.9). Analysing eGFR reduction ≥30% as a surrogate endpoint (148/400), the time from dnDSA to this event was 2.0 years (IQR 0.6-4.2), with a positive predictive value (PPV) of 45.9% to predict graft loss, which occurred after 2.0 years (IQR 0.8-3.2). The median time from proteinuria ≥500 mg/g and ≥1000 mg/g to graft failure was identical, 1.8 years, with a PPV of 43.8% and 49.0%, respectively. Composite endpoints did not improve PPV. Multivariable analysis showed that rejection was the most important independent risk factor for all renal endpoints and graft loss.

CONCLUSIONS

Renal function, proteinuria and rejection are strongly associated with graft failure in patients with dnDSA and may serve as surrogate endpoints.

Для цитирования: López Del Moral Covadonga, Wu Kaiyin, Naik Marcel, Osmanodja Bilgin, Akifova Aylin, Lachmann Nils, Stauch Diana, Hergovits Sabine, Choi Mira, Bachmann Friederike, Halleck Fabian, Schrezenmeier Eva, Schmidt Danilo, Budde Klemens. Predictors of graft failure after first detection of de novo donor-specific HLA antibodies in kidney transplant recipients.. Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 2023. DOI: 10.1093/ndt/gfad149.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.