Pulmonary annulus growth after the modified Blalock-Taussig shunt in tetralogy of Fallot.

Nakashima Kouki, Itatani Keiichi, Oka Norihiko, Kitamura Tadashi, Horai Tetsuya, Hari Yosuke, Miyaji Kagami

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In tetralogy of Fallot (TOF), it is well known that postoperative pulmonary regurgitation reduces right ventricular function during long-term follow-up. Complete repair without a transannular patch should help avoid pulmonary regurgitation. Recently, primary complete repair has been preferred to the staged repair with use of a Blalock-Taussig shunt (BTS) even in neonates or small infants; however, little has been reported about the influence of a BTS on pulmonary annular growth.

METHODS

We examined 40 patients with TOF or double-outlet right ventricle with pulmonary stenosis. Twenty-one patients received a BTS before complete repair, whereas 19 patients underwent primary complete repair. Pulmonary annular size was measured by echocardiography before BTS, complete repair, or both, and ventricular volume was measured by cardiac catheterization.

RESULTS

There were no significant differences in complete repair age or body size between the groups. Pulmonary annulus sizes in the BTS group were smaller than those in the primary repair group (Z score, -5.1 ± 2.5 vs -3.7 ± 1.8). After the BTS, significant annular growth (Z score, -2.8 ± 2.1) was observed (p = 0.0028), with a significant increase in left ventricular end-diastolic volume (p = 0.015). When patients with severe pulmonary stenosis (Z score > -7.0) were excluded, pulmonary annular preservation at complete repair was achieved in 64.7% (11/17) of the BTS group and 36.8% (7/19) of the primary repair group (p = 0.088).

CONCLUSIONS

The BTS increased the pulmonary annular size and the left ventricular volume during the 6 months before complete repair, resulting in preservation of the pulmonary valve function.

Для цитирования: Nakashima Kouki, Itatani Keiichi, Oka Norihiko, Kitamura Tadashi, Horai Tetsuya, Hari Yosuke, Miyaji Kagami. Pulmonary annulus growth after the modified Blalock-Taussig shunt in tetralogy of Fallot.. The Annals of thoracic surgery. 2014. DOI: 10.1016/j.athoracsur.2014.04.083.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.