MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1164/ajrccm.159.1.9803119

Медицинская библиотека · American journal of respiratory and critical care medicine · 1999

Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors.

Fink J B, Dhand R, Grychowski J, Fahey P J, Tobin M J

Сравнительное исследованиеСтатьяПоддержка правительства СШАПеревод в очереди

Аннотация

We attempted to resolve the discrepancies in reported data on aerosol deposition from a chlorofluorocarbon (CFC)-propelled metered-dose inhaler (MDI) during mechanical ventilation, obtained by in vivo and in vitro methodologies. Albuterol delivery to the lower respiratory tract was decreased in a humidified versus a dry circuit (16.2 versus 30.4%, respectively; p < 0.01). In 10 mechanically ventilated patients, 4.8% of the nominal dose was exhaled. When the exhaled aerosol was subtracted from the in vitro delivery of 16.2% achieved in a humidified ventilator circuit, the resulting value (16.2 - 4.8 = 11.4%) was similar to in vivo estimates of aerosol deposition. Having reconciled in vitro with in vivo findings, we then evaluated factors influencing aerosol delivery. A lower inspiratory flow rate (40 versus 80 L/min; p < 0.001), a longer duty cycle (0.50 versus 0.25; p < 0.04), and a shorter interval between successive MDI actuations (15 versus 60 s; p < 0.02) increased aerosol delivery, whereas use of a hydrofluoroalkane (HFA)-propelled MDI decreased aerosol delivery compared with the CFC-propelled MDI. A MDI and actuator combination other than that designed by the manufacturer altered aerosol particle size and decreased drug delivery. In conclusion, aerosol delivery in an in vitro model accurately reflects in vivo delivery, providing a means for investigating methods to improve the efficiency of aerosol therapy during mechanical ventilation.

Для цитирования: Fink J B, Dhand R, Grychowski J, Fahey P J, Tobin M J. Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors.. American journal of respiratory and critical care medicine. 1999. DOI: 10.1164/ajrccm.159.1.9803119.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.