MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1532-950x.2007.00317.x

Медицинская библиотека · Veterinary surgery : VS · 2007

Comparison of 99mTcO4(-) trans-splenic portal scintigraphy with per-rectal portal scintigraphy for diagnosis of portosystemic shunts in dogs.

Sura Patricia A, Tobias Karen M, Morandi Federica, Daniel Gregory B, Echandi Rita L

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate trans-splenic portal scintigraphy (TSPS) and per-rectal portal scintigraphy (PRPS) for diagnosis of congenital portosystemic shunts (CPSS) in dogs, and compare these results with surgical findings.

STUDY

DESIGN

Prospective, randomized cross over clinical trial.

ANIMALS: Dogs (n=42) with suspected CPSS.

METHODS

Dogs had TSPS and PRPS 48 hours apart; quantity of radionuclide administered was recorded. Three independent, blinded reviewers evaluated each scintigraphic study for study quality, shunt presence, number, and location of shunt termination (caudal vena cava, azygos vein). All dogs had exploratory celiotomy. Negative scintigraphic findings were confirmed with intraoperative mesenteric portography. Ameroid constrictors were placed on all extrahepatic CPSS, and hepatic biopsies were obtained.

RESULTS

TSPS was 100% sensitive and specific for diagnosis of CPSS and significantly (P<.05) more likely than PRPS to detect shunt number and termination. Interpretation was consistent between observers, and TSPS required significantly less radionuclide than PRPS.

CONCLUSION

TSPS was as sensitive as PRPS for detection of shunting vessels, and consistently yielded studies of higher quality, allowing detection of shunt number and location with consistent interpretation among radiologists.

CLINICAL RELEVANCE: TSPS provides information about shunt number and location, which allows improved surgical planning. Because it requires significantly less radionuclide, TSPS improves safety, allows for more comprehensive patient care, and earlier surgical intervention.

Для цитирования: Sura Patricia A, Tobias Karen M, Morandi Federica, Daniel Gregory B, Echandi Rita L. Comparison of 99mTcO4(-) trans-splenic portal scintigraphy with per-rectal portal scintigraphy for diagnosis of portosystemic shunts in dogs.. Veterinary surgery : VS. 2007. DOI: 10.1111/j.1532-950x.2007.00317.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.