DOI 10.1016/j.resuscitation.2024.110345

Медицинская библиотека · Resuscitation · 2024

Optimization of manual ventilation quality using respiratory function monitoring in neonates: A two-phase intervention trial.

Dvorsky Robyn, Bibl Katharina, Lietz Andrea, Haderer Moritz, Klebermaß-Schrehof Katrin, Werther Tobias, Schmölzer Georg M, Berger Angelika, Wagner Michael

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was the evaluation of the impact of a respiratory function monitor (RFM, Neo100, Monivent AB, Gothenburg, Sweden) on the quality of ventilation in neonates.

METHODS

This single-center two-phase intervention study was conducted at the Neonatal Intensive Care Unit and the delivery room of the Medical University of Vienna. Patients with clinical need for positive pressure ventilation were included in either of two consecutive study phases: (i) patients were ventilated with a hidden RFM (control) or (ii) visible RFM (intervention) during manual positive pressure ventilations. The duration of each phase was approximately six months. The primary outcome was the percentage of ventilations within a tidal volume range of 4-8 ml/kg (pVTe).

RESULTS

A total of 90 patients (GA 22-66 weeks) were included. The primary outcome was significantly higher in the intervention group with a visible RFM (53.7%, SD 22.6) than in the control group without the monitor (37.3%, SD 20.5); (p < 0.001, mean difference [i.e., change in percentage points]: 16.95% CI: 7.4-35). In terms of secondary outcomes, excessive tidal volumes (>8ml/kg), potentially associated with an increased risk of brain injury, could be significantly reduced when a RFM was visible during ventilation (10.9% [IQR 26.4] vs. 29.5% [IQR 38.1]; p = 0.004). Furthermore, mask leakage could be significantly decreased (37.3% [SD 22.7] vs. 52.7% [SD 23.0]; p = 0.002).

CONCLUSION

Our results suggest that the clinical application of a RFM for manual ventilation of preterm and term infants leads to a significant improvement in ventilation parameters.

Для цитирования: Dvorsky Robyn, Bibl Katharina, Lietz Andrea, Haderer Moritz, Klebermaß-Schrehof Katrin, Werther Tobias, Schmölzer Georg M, Berger Angelika, Wagner Michael. Optimization of manual ventilation quality using respiratory function monitoring in neonates: A two-phase intervention trial.. Resuscitation. 2024. DOI: 10.1016/j.resuscitation.2024.110345.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.