MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1067/mpr.2000.109377

Медицинская библиотека · The Journal of prosthetic dentistry · 2000

In vitro and in vivo corrosion evaluation of nickel-chromium- and copper-aluminum-based alloys.

Benatti O F, Miranda W G, Muench A

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

STATEMENT OF PROBLEM: The low resistance to corrosion is the major problem related to the use of copper-aluminum alloys.

PURPOSE: This in vitro and in vivo study evaluated the corrosion of 2 copper-aluminum alloys (Cu-Al and Cu-Al-Zn) compared with a nickel-chromium alloy.

MATERIAL AND

METHODS

For the in vitro test, specimens were immersed in the following 3 corrosion solutions: artificial saliva, 0.9% sodium chloride, and 1.0% sodium sulfide. For the in vivo test, specimens were embedded in complete dentures, so that one surface was left exposed. The 3 testing sites were (1) close to the oral mucosa (partial self-cleaning site), (2) surface exposed to the oral cavity (self-cleaning site), and (3) specimen bottom surface exposed to the saliva by means of a tunnel-shaped perforation (non-self-cleaning site).

RESULTS

Almost no corrosion occurred with the nickel-chromium alloy, for either the in vitro or in vivo test. On the other hand, the 2 copper-aluminum-based alloys exhibited high corrosion in the sulfide solution. These same alloys also underwent high corrosion in non-self-cleaning sites for the in vivo test, although minimal attack was observed in self-cleaning sites.

CONCLUSION

The nickel-chromium alloy presented high resistance to corrosion. Both copper-aluminum alloys showed considerable corrosion in the sulfide solution and clinically in the non-self-cleaning site. However, in self-cleaning sites these 2 alloys did not show substantial corrosion.

Для цитирования: Benatti O F, Miranda W G, Muench A. In vitro and in vivo corrosion evaluation of nickel-chromium- and copper-aluminum-based alloys.. The Journal of prosthetic dentistry. 2000. DOI: 10.1067/mpr.2000.109377.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.