DOI 10.1097/mnm.0000000000001487
Lesion detection in 18F-sodium fluoride bone imaging: a comparison of attenuation-corrected versus nonattenuation-corrected PET reconstructions from modern PET-CT systems.
Аннотация
OBJECTIVES
An earlier study demonstrated comparable lesion detection between attenuation-corrected (AC) and nonattenuation-corrected (NAC) 18F-sodium fluoride (NaF) PET images, which is relevant for computed tomography (CT) radiation dose-saving. However, this finding may not be applicable to newer systems. The aim was to compare lesion detection between AC and NAC NaF PET images on modern PET-CT systems.
METHODS
One expert and one nonexpert observer retrospectively surveyed NaF PET data in 25 breast cancer patients. At both lesion and patient level, each observer classified bone abnormalities as malignant, equivocal or benign, from NAC and AC PET images in the absence of CT. Expert interpretation of NaF PET-CT with the review of all diagnostic imaging/pathology reports for at least the subsequent 12 months provided reference standard metastases status at the patient level. Two-tailed Wilcoxon signed-rank tests measured statistically significant differences in total lesion detection between AC and NAC PET. Quadratic-weighted kappa score measured agreement in patient metastases status between observers.
RESULTS
On a lesion-basis, AC PET images showed significantly more lesions than NAC for both the expert (122 versus 96; P = 0.002) and nonexpert (146 versus 132; P = 0.036) observers, with a large number of patients demonstrating disparity between AC and NAC images. For metastases status at the patient level without CT, NAC PET showed slightly better diagnostic accuracy than AC due to fewer false-positive results, as fewer lesions were identified.
CONCLUSION
AC PET data provided superior lesion detection to NAC in NaF bone examinations and are thus required for clinical interpretation.