MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.rec.2018.07.003

Медицинская библиотека · Revista espanola de cardiologia (English ed.) · 2018

Use of Intra-aortic Balloon Pump as a Bridge to Heart Transplant in Spain: Results From the ASIS-TC Study.

Barge-Caballero Eduardo, González-Vílchez Francisco, Delgado Juan F, Mirabet-Pérez Sonia, González-Costello José, Pérez-Villa Félix, Martínez-Sellés Manuel, Segovia-Cubero Javier, Hervás-Sotomayor Daniela, Blasco-Peiró Teresa, De la Fuente-Galán Luis, Lambert-Rodríguez José Luis, Rangel-Sousa Diego, Almenar-Bonet Luis, Garrido-Bravo Iris P, Rábago-Juan-Aracil Gregorio, Muñiz Javier, Crespo-Leiro María G

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

INTRODUCTION AND

OBJECTIVES

In Spain, intra-aortic balloon pump (IABP) has been used frequently as a bridge to urgent heart transplant (HT). We sought to analyze the clinical outcomes of this strategy.

METHODS

We conducted a case-by-case, retrospective review of clinical records of 281 adult patients listed for urgent HT under IABP support in 16 Spanish institutions from 2010 to 2015. Pre- and post-transplant survival and adverse clinical events were analyzed.

RESULTS

A total of 194 (69%, 95%CI, 63.3-74.4) patients were transplanted and 20 (7.1%, 95%CI, 4.4-10.8) died during a mean period of IABP support of 10.9±9.7 days. IABP support was withdrawn before an organ became available in 32 (11.4%) patients. Thirty-five (12.5%, 95%CI, 8.8-16.9) patients transitioned from IABP to full-support mechanical devices. Mean urgent waiting list time increased from 5.9±6.3 days in 2010 to 15±11.7 days in 2015 (P=.001). Post-transplant survival rates at 30-days, 1-year, and 5-years were 88.1% (95%CI, 85.7-90.5), 76% (95%CI, 72.9-79.1), and 67.8% (95%CI, 63.7-71.9), respectively. The incidence rate of major adverse clinical outcomes-device dysfunction, stroke, bleeding or infection-during IABP support was 26 (95%CI, 20.6-32.4) episodes per 1000 patient-days. The incidence rate of IABP explantation due to complications was 7.2 (95%CI, 4.5-10.8) cases per 1000 patient-days.

CONCLUSIONS

In a setting of short waiting list times, IABP can be used to bridge candidates to urgent HT with acceptable postoperative results, but there were significant rates of adverse clinical events during support.

Для цитирования: Barge-Caballero Eduardo, González-Vílchez Francisco, Delgado Juan F, Mirabet-Pérez Sonia, González-Costello José, Pérez-Villa Félix, Martínez-Sellés Manuel, Segovia-Cubero Javier, Hervás-Sotomayor Daniela, Blasco-Peiró Teresa, De la Fuente-Galán Luis, Lambert-Rodríguez José Luis, Rangel-Sousa Diego, Almenar-Bonet Luis, Garrido-Bravo Iris P, Rábago-Juan-Aracil Gregorio, Muñiz Javier, Crespo-Leiro María G. Use of Intra-aortic Balloon Pump as a Bridge to Heart Transplant in Spain: Results From the ASIS-TC Study.. Revista espanola de cardiologia (English ed.). 2018. DOI: 10.1016/j.rec.2018.07.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.