Dose enhancement by gold, iron oxide, bismuth oxide, and platinum nanoparticles in radiotherapy: a comprehensive meta-analysis.

Malekzadeh Reza, Gholami Shima, Mehrabifard Mahboobeh, Khoshdel Emad, Alipour Bahman, Shifteh Naser, Abdollahi Behnaz Babaye, Farajollahi Ali Reza

СтатьяМетаанализПеревод в очереди

Аннотация

This first global comprehensive meta-analysis of 64 studies compares four metal (gold (Au), iron oxide (IO), bismuth oxide (BO), platinum (Pt)) nanoparticles (NPs) as cancer radiosensitizers. Following PRISMA guidelines, we searched PubMed/Medline, Scopus, Web of Science, and Cochrane Library through November 2025 for studies on four metal NPS as cancer radiosensitizers. Meta-analysis calculated pooled dose enhancement factor (DEF) with comprehensive publication bias assessment (Egger’s, Begg’s, Trim-and-Fill, Fail-Safe N) and sensitivity analyses. Subgroup analyses examined nanoparticle size (≤ 10 nm, 10–30 nm, > 30 nm), radiation energy (≤ 100 keV, 100–250 keV, > 250 keV), and cancer cell line effects. Meta-regression evaluated size as a continuous predictor. Analysis of 95 independent data comparing four NPs revealed BO as most efficacious (0.575; 95% CI: 0.352–0.798; p = 0.001), followed by Au (0.395; 95% CI: 0.317–0.474; p = 0.001) and IO (0.293; 95% CI: 0.153–0.433; p = 0.001). Pt showed highest point estimate (0.780; 95% CI: 0.306–1.255; p = 0.001) but critically fragile evidence (Fail-Safe N = 2). Smaller NPs (≤ 10 nm, 0.500; 95% CI: 0.300–0.700) demonstrated 60% greater efficacy than 10–30 nm particles (0.312; 95% CI: 0.180–0.430). Orthovoltage radiation (≤ 100 keV0.710; 95% CI: 0.410–1.150) produced 2-fold greater enhancement than megavoltage (> 250 keV, 0.350; 95% CI: 0.240–0.460). Sensitivity analysis confirmed no influential outliers, with bismuth showing exceptional robustness (± 6% variation). BO is the optimal radiosensitizer, demonstrating highest efficacy with unbiased evidence. Smaller NPs (≤ 10 nm) and orthovoltage radiotherapy protocols maximize radiosensitization enhancement.

Для цитирования: Malekzadeh Reza, Gholami Shima, Mehrabifard Mahboobeh, Khoshdel Emad, Alipour Bahman, Shifteh Naser, Abdollahi Behnaz Babaye, Farajollahi Ali Reza. Dose enhancement by gold, iron oxide, bismuth oxide, and platinum nanoparticles in radiotherapy: a comprehensive meta-analysis.. Radiological physics and technology. 2026. DOI: 10.1007/s12194-026-01009-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.