MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jssc.201100165

Медицинская библиотека · Journal of separation science · 2011

Simultaneous extraction of acidic and basic drugs from urine using mixed-mode monolithic silica spin column bonded with octadecyl and cation-exchange group.

Namera Akira, Yamamoto Shinobu, Saito Takeshi, Miyazaki Shota, Oikawa Hiroshi, Nakamoto Akihiro, Nagao Masataka

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A method coupling spin column extraction with gas chromatography-mass spectrometry was developed for the simultaneous extraction of acidic and basic drugs from urine. Benzodiazepines, local anaesthetics, antidepressants, and barbiturates were used as model drugs. Sample loading, washing, and elution of the target drugs were accomplished by centrifugation of the column. In this study, mixed-mode monolithic silica bonded with a C18 reversed-phase and a strong cation exchange phase was packed in a spin column. The pH of a urine sample (0.2 mL) was adjusted to 3 and the analytes adsorbed onto the column were eluted with 0.1 mL of MeOH containing 2% NH3; all the tested drugs were simultaneously extracted from urine. The recovery of the tested drugs was 65-123%. Up to a concentration of 2500 ng/mL of the target drugs in urine, a linear curve was observed (r(2)>0.996). The intra- and interday RSDs at three different concentrations in urine were 2.1-14.7%. For RSDs lower than 15%, the limits of detection were 1-25 ng/mL. The proposed method was successfully applied for clinical and forensic cases and the results thus obtained were in good agreement with those obtained by conventional methods.

Для цитирования: Namera Akira, Yamamoto Shinobu, Saito Takeshi, Miyazaki Shota, Oikawa Hiroshi, Nakamoto Akihiro, Nagao Masataka. Simultaneous extraction of acidic and basic drugs from urine using mixed-mode monolithic silica spin column bonded with octadecyl and cation-exchange group.. Journal of separation science. 2011. DOI: 10.1002/jssc.201100165.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.