A woman was admitted to hospital in the 39th week of gestation due to syncope, followed by nausea and headache. The patient's history revealed a 10-hour, unintentional exposure to carbon monoxide (CO), secondary to burning charcoal for indoor heating. Because of monitored fetal distress, a cesarean section was performed. The newborn had an Apgar score of 4, 9, and 10 at 1, 5, and 10 minutes post-delivery, respectively. The 1-minute Apgar was low due to lack of spontaneous breathing, reduced tonus, bluish coloration, and reduced response to pain. The neonate's carboxyhemoglobin level seven hours post-CO exposure was 22%, and arterial pH was 7.28. Neurological examination 30 minutes after delivery showed no pathology. The neonate was treated with 100% normobaric oxygen for 12 hours. We discuss the treatment options for fetal CO poisoning and specific considerations that had to be taken into account in the present case.

Для цитирования: Bar Ronen, Cohen Maxim, Bentur Yedidia, Shupak Avi, Adir Yochai. Pre-Labor exposure to carbon monoxide: should the neonate be treated with hyperbaric oxygenation?. Clinical toxicology (Philadelphia, Pa.). 2007. DOI: 10.1080/15563650701382763.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.