Assessing the Influence of Implant Scan Body Material on Desktop Scanner Accuracy: An In Vitro Study.

Şahin Nurşen, Kaleli Necati, Nazlı Tekin Elif, Ural Çağrı

СтатьяПеревод в очереди

Аннотация

There are limited studies analyzing the accuracy of desktop scanners with scan bodies made of different materials but of the same design. The purpose of this in vitro study is to examine the effect of scan bodies made of titanium and polyetheretherketone (PEEK) on the accuracy of desktop scanners that have different scanning technologies (white light vs blue light). Two upper jaw models with a missing left second premolar were obtained. An implant (Bilimplant) was placed in the area where the missing tooth was located. The titanium and PEEK scan bodies were torqued, and an industrial scanner obtained reference data. A total of 40 scans were recorded using two desktop scanners (Dentium and Kivi). Ti-Dentium, Ti-Kivi, PEEK-Dentium, and PEEK-Kivi were identified as the four test groups. Each STL file was imported into Geomagic for reverse engineering. The deviation between the experimental scan and the reference data was analyzed using a best-fit algorithm to determine the accuracy of each scan. Deviation values were compared using nonparametric tests. The average deviation values ± standard deviation observed across the groups were 65 ± 4.5 μm, 81 ± 3.1 μm, 24 ± 5.4 μm, and 47 ± 9.1 μm, respectively. Group Ti-K exhibited the highest average deviation, whereas Group PEEK-D demonstrated the lowest. A statistically significant difference was found between all groups (P < .05). Within the limitations of this in vitro study, PEEK scan bodies and white light scanners demonstrated superior accuracy, which may be clinically relevant in high-precision implant restorations.

Для цитирования: Şahin Nurşen, Kaleli Necati, Nazlı Tekin Elif, Ural Çağrı. Assessing the Influence of Implant Scan Body Material on Desktop Scanner Accuracy: An In Vitro Study.. The Journal of oral implantology. 2026. DOI: 10.1563/aaid-joi-d-25-00133.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.