MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jat/33.6.294

Медицинская библиотека · Journal of analytical toxicology · 2009

Simultaneous measurement of indandione-type rodenticides in human serum by liquid chromatography-electrospray ionization- tandem mass spectrometry.

Jin Mi-cong, Cai Mei-qiang, Chen Xiao-hong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Measurement of indandione rodenticides is important in the diagnosis and treatment of accidental rodenticide ingestion. Current assays lack effective measurements for simultaneous analysis of the indandiones, especially the isomers. The intent of this study was to establish a novel and selective method for the simultaneous determination of indandione-type rodenticides (diphacinone, chlorophacinone, valone, and pindone) in human serum by liquid chromatography-electrospray ionization-tandem mass spectrometry. After addition of internal standard, the sample was extracted with 10% methanol in acetonitrile and cleaned by solid-phase extraction (SPE). The analytes were separated on a C(18) rapid column and infused into an ion trap mass spectrometer in the negative electrospray ionization mode. The multiple-reaction monitoring ion pairs were m/z 339 --> 167, m/z 373 --> 201, m/z 229 --> 145, m/z 229 --> 172, and m/z 307 --> 161 for diphacinone, chlorophacinone, valone, pindone, and IS, respectively. Recoveries were between 81.5 and 94.6%, and the limits of quantification were 0.2 to 0.5 ng/mL. Intra- and interday RSDs were less than 7.9 and 11.5%, respectively. The assay was linear in the range of 0.5-100.0 ng/mL with coefficients of determination (r(2) > 0.99) for all analytes. The proposed method enables the unambiguous confirmation and quantification of the indandiones in both clinical and forensic specimens.

Для цитирования: Jin Mi-cong, Cai Mei-qiang, Chen Xiao-hong. Simultaneous measurement of indandione-type rodenticides in human serum by liquid chromatography-electrospray ionization- tandem mass spectrometry.. Journal of analytical toxicology. 2009. DOI: 10.1093/jat/33.6.294.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.