MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ihj.2015.02.020

Медицинская библиотека · Indian heart journal · 2015

Renal sympathetic denervation using an externally irrigated radiofrequency ablation catheter for treatment of resistant hypertension - Acute safety and short term efficacy.

Yalagudri Sachin, Raju Narayana, Das Bharati, Daware Ashwin, Maiya Shreesha, Jothiraj Kannan, Ravikishore A G

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study was conducted to assess the acute safety and short term efficacy of renal sympathetic denervation (RSDN) using solid tip radiofrequency ablation (RFA) catheter and saline irrigation through the renal guiding catheter to achieve effective denervation.

BACKGROUND

RSDN using a specialized solid-tip RFA catheter has recently been demonstrated to safely reduce systemic blood pressure in patients with refractory hypertension, the limitation being inadequate power delivery in renal arteries. So, we used solid-tip RFA catheter along with saline irrigation for RSDN.

METHODS

Nine patients with resistant hypertension underwent CT and conventional renal angiography, followed by bilateral or unilateral RSDN using 5F RFA catheter with saline irrigation through renal guiding catheter. Repeat renal angiography was performed at the end of the procedure. In all patients, pre- and post-procedure serum creatinine was measured.

RESULTS

Over 1-month period: 1) the systolic/diastolic blood pressure decreased by -57 ± 20/-25 ± 7.5 mm Hg; 2) all patients experienced a decrease in systolic blood pressure of at least -36 mm Hg (range 36-98 mm Hg); 3) there was no evidence of renal artery injury immediate post-procedure. There was no significant change in serum creatinine level.

CONCLUSIONS

This data shows the acute procedural safety and short term efficacy of RSDN using modified externally irrigated solid tip RFA catheter.

Для цитирования: Yalagudri Sachin, Raju Narayana, Das Bharati, Daware Ashwin, Maiya Shreesha, Jothiraj Kannan, Ravikishore A G. Renal sympathetic denervation using an externally irrigated radiofrequency ablation catheter for treatment of resistant hypertension - Acute safety and short term efficacy.. Indian heart journal. 2015. DOI: 10.1016/j.ihj.2015.02.020.