Sterility of Tranexamic Acid Syringes Prefilled by Tactical Combat Medics in a Garrison Setting.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sourbeer Janelle, Yallowitz Aaron, Zarow Gregory J, Garcia Keri E, Allen David S, Iteen Alexander, McGowan Andrew J, Morrison Theodore C, Tovar Matthew A, Sulava Eric F, Bianchi William D

Аннотация

BACKGROUND: Tranexamic acid (TXA) is an antifibrinolytic agent that confers a significant mortality benefit in the treatment of hemorrhagic trauma. The benefit of TXA is timedependent; Special Operations Tactical Medics (SOTM) and Special Operations Independent Duty Corpsmen (SOIDC) commonly prefill TXA syringes prior to a mission. However, the sterility of prefilled TXA syringes remains unclear.

METHODS: SOTMs (n=40) and SOIDCs (n=11) each filled two syringes with TXA in a garrison-type training setting using their customary preparation technique. As controls, a trained clinical research coordinator (CRC) filled 51 TXA syringes in the garrison setting and 51 in a Level-II Biosafety Lab (n=204 syringes total). In all cases, TXA was drawn from a glass vial into a 10cc syringe. TXA syringes were stored at room temperature, plated on chocolate agar at 0-, 3-, 6-, and 9-day intervals from collection (n=816 plates total), incubated for 7 days, then observed for bacterial growth.

RESULTS: The observed positivity rate of 0.6% (5 of 816 plates) was statistically similar to the published false positive rate of 0.5% for chocolate agar (P=.68). Positivity rates did not significantly differ by garrison setting versus lab setting (P=.20), SOTM/SOIDC versus CRC (P=.18), or day of testing (P=.26). One TXA syringe demonstrated contamination on Day 9.

CONCLUSION: Present findings suggest that TXA syringes prepared in a simulated operational environment can maintain sterility up to 6 days when stored at room temperature. These results directly inform the Committee on Tactical Combat Casualty Care (CoTCCC) regarding the safe storage duration of prefilled TXA syringes.