MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00216-024-05511-6

Медицинская библиотека · Analytical and bioanalytical chemistry · 2024

Dual response signal CdTe QDs@ZIF-8 with butterfly spectrum for dual-mode fluorescence/colorimetric detection of tetracycline in animal feeds.

Hui Yingfei, Wang Mingyue, Liu Yinsheng, Peng Liping, Tian Jiaying, Ren Borong, Guo Hao, Yang Wu

СтатьяПеревод в очереди

Аннотация

In this study, a ratiometric fluorescent sensor CdTe QDs@ZIF-8 with butterfly spectra is successfully constructed by in situ encapsulating mercaptopropionic acid-modified CdTe quantum dots in zeolitic imidazolate framework-8 (ZIF-8) with a simple strategy, and used for the detection of tetracycline in fluorescence/smartphone colorimetry dual-mode. ZIF-8 not only reduces the agglomeration of the quantum dots but also surprisingly generates a new green fluorescence signal at 524 nm while the red fluorescence of the CdTe quantum dots at 650 nm quenches when tetracycline is added. The two opposing fluorescence signals create a butterfly-shaped fluorescence spectrum, allowing the sensor to detect tetracycline over a linear range of 0-70 μM with the detection limit (LOD) of 0.0155 μM by using a ratiometric fluorescence technique. What is more, based on the obvious color change of the fluorescent sensor gradually from red to green under UV light, a highly stable point-of-care testing sensor has been developed for on-site detection of tetracycline through color recognition by smartphones, which can be used for real-time detection of this antibiotic in the range of 0-1000 μM with the LOD of 0.0249 μM. This work provides a simple and efficient method for the on-site detection of tetracycline.

Для цитирования: Hui Yingfei, Wang Mingyue, Liu Yinsheng, Peng Liping, Tian Jiaying, Ren Borong, Guo Hao, Yang Wu. Dual response signal CdTe QDs@ZIF-8 with butterfly spectrum for dual-mode fluorescence/colorimetric detection of tetracycline in animal feeds.. Analytical and bioanalytical chemistry. 2024. DOI: 10.1007/s00216-024-05511-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.