Intraoperative hybrid cardiac surgery for neonates and young children with congenital heart disease: 5 years of experience.

Li Shou-Jun, Zhang Hao, Sheng Xiang-Dong, Yan Jun, Deng Xi-Cheng, Chen Wei-Dan, Hu Sheng-Shou

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

This study intends to summarize 5 years of intraoperative hybrid procedure (IHP) experience with neonates and young children having congenital heart disease (CHD).

METHODS

From March 2003 to March 2009, a total of 152 consecutive patients younger than 2 years old who had undergone IHP were enrolled. In the balloon plasty group (n = 72), transventricular pulmonary valvuloplasty, or transaortic balloon dilatation were performed for pulmonary atresia, pulmonary stenosis, or coactation of the aorta. In the device group (n = 43), transventricular device closure was performed for ventricular septal defect (VSD), or transatrial device closure for atrial septal defect (ASD). In the collateral arteries occlusion group (n = 37), the major aortopulmonary collateral arteries (MPCAs) were occluded with coils for tetralogy of Fallot or other cyanotic CHDs. All procedures were image guided and performed in a specially designed hybrid operation room. All surviving patients were followed up, and the major adverse cardiovascular events that occurred were recorded.

RESULTS

In the balloon plasty group, all patients received successful transventricular valvuloplasty or transaortic balloon angioplasty. However, severe right ventricle outflow obstruction was observed in 2 cases. One patient was transferred to regular open-heart surgery immediately, and another underwent regular open-heart procedure after discharge. Furthermore, 1 neonate with pulmonary atresia with intact ventricular septum died from liver failure 6 months after IHP. In the device closure group, the device closure failed to be performed in 3 cases (2 with ASD and 1 with VSD). One young child with VSD died from pneumonia, even after successful device closure. No device malposition was observed in the device closure group during follow-up. All patients who received MPCA occlusion and associated open-heart correction were eventually discharged.

CONCLUSION

IHP could avoid or shorten the application of cardiopulmonary bypass and reduce surgical trauma for selected young children with CHD. Although IHP is feasible and safe, the image outfits, image-guided technology, and IHP-related devices should be developed and improved.

Для цитирования: Li Shou-Jun, Zhang Hao, Sheng Xiang-Dong, Yan Jun, Deng Xi-Cheng, Chen Wei-Dan, Hu Sheng-Shou. Intraoperative hybrid cardiac surgery for neonates and young children with congenital heart disease: 5 years of experience.. Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia. 2010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.