Morphofunctional Outcomes of 3D Heads-Up Visualization Versus Standard Operating Microscopy in Idiopathic Epiretinal Membrane Surgery: A Prospective Randomized Study.
Аннотация
Background/
Objectives
Three-dimensional (3D) heads-up visualization systems are increasingly used in vitreoretinal surgery and may offer advantages in intraoperative visualization, ergonomics, surgical education, and reduced light exposure. This study aimed to compare morphofunctional outcomes, intraoperative parameters, postoperative complications, and surgical team satisfaction between 3D heads-up visualization and standard operating microscopy in idiopathic epiretinal membrane (ERM) surgery.
Methods
In this prospective randomized study, 25 eyes of 25 patients with idiopathic ERM were assigned to surgery using either a 3D heads-up visualization system (3D group, n = 13) or a standard operating microscope (SOM group, n = 12). BCVA, CMT, mfERG parameters, intraoperative variables, postoperative OCT-based macular complications, and satisfaction scores were evaluated. No formal sample-size calculation was performed; therefore, all analyses should be interpreted as exploratory and hypothesis-generating.
Results
Postoperative BCVA and CMT were not significantly different between the two groups at both 1 and 3 months, suggesting that no major between-group difference was detected in final short-term visual and anatomical outcomes compared with standard operating microscopy in macular surgery. However, the 3D group had significantly worse preoperative BCVA, which may have inflated unadjusted change-score estimates. Therefore, the greater ΔBCVA observed in the 3D group should not be interpreted as evidence of superior efficacy.
Conclusions
In idiopathic ERM surgery, 3D heads-up visualization showed no statistically significant difference in final anatomical and visual outcomes compared with standard operating microscopy, while allowing significantly lower endoillumination settings during peeling. The findings support its feasibility as an alternative visualization platform; however, they do not establish superiority, equivalence, or safety because of the exploratory design, small sample size, short follow-up, and baseline imbalances.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.