Introduction
Periprosthetic femoral fracture (PPF) is a serious complication following total hip arthroplasty (THA) [ 1 ]. With an aging population and the success of arthroplasty procedures, the number of joint replacements has increased significantly over the past decade. As THA becomes more common and life expectancy rises, the incidence of PPF has also grown [ 2 ]. The reported incidence ranges from approximately 1% after primary THA to 4% after revision THA [ [3] , [4] , [5] ]. This trend is expected to continue, with projections suggesting an increasing rate of THA procedures and a corresponding rise in PPF cases through 2030 [ 6 ].
Several classification systems have been proposed for PPFs, with the Vancouver classification by Duncan et al. being the most widely accepted one [ 7 , 8 ]. This system categorizes fractures based on their location, the stability of the femoral component, and the quality of the remaining bone stock [ 7 , 9 , 10 ]. In cases where the prosthesis is loose, and there is deficient proximal bone stock in the femur (Vancouver Type B3 fractures), revision of the femoral component and prosthesis exchange is recommended. This approach addresses both the instability of the prosthesis and the fracture itself by providing intramedullary support through the use of long-stemmed implants commonly employed in revision procedures [ 11 , 12 ]. During revision, the prosthesis can be replaced with either a cemented or non-cemented stemmed implant. However, cemented stems carry the risk of cement forced into the fracture site, potentially impeding union and healing. In addition, the effectiveness of modular, non-cemented stems in Vancouver Type B3 fractures, particularly when used with extended trochanteric osteotomies, remains uncertain, especially when the distal femur has poor bone quality [ 8 , 11 ].
To the best of our knowledge, this study is the first to treat 22 patients with PPFs and poor bone stock using a monoblock cementless long-stem prosthesis, with cement fixation applied only to the distal portion of the stem. We describe the technique, report the outcomes, and provide the clinical follow-up for both cases.
Case histories
Case 1
A 70-year-old woman presented to the emergency department with a 3-day history of right groin pain. Her medical history was significant for multiple myeloma (MM) and a right femoral neck fracture treated 1 month prior with a cemented bipolar hemiarthroplasty using a CORAIL stem (Depuy Synthes, Raynham, MA). Following hemiarthroplasty, the patient commenced accelerated weight-bearing with a walker. In addition, she had undergone a left THA for hip osteoarthritis approximately 10 years earlier.
Upon clinical examination, the patient exhibited tenderness in the right hip region. In addition, inflammatory markers, including erythrocyte sedimentation rate and C-reactive protein, were evaluated to exclude the possibility of infection. Radiographic imaging, including anteroposterior and lateral views of the pelvis, revealed a PPF, classified as Vancouver type B3 ( Fig. 1 ). Given these findings, a decision was made to perform revision arthroplasty. Figure 1 Preoperative radiograph of case 1.

Surgical procedure
Revision surgery was conducted under general anesthesia with the patient positioned laterally. A lateral approach was used to access the hip. Intraoperatively, acetabular damage was identified, necessitating reaming of the acetabular fossa. A 47-mm cemented ZCA All-Poly acetabular cup (Zimmer, Warsaw, Indiana) was implanted. The cement mantle and femoral stem were removed through the PPF site. To prevent fracture propagation during reaming and stem impaction, a prophylactic cerclage wire was placed 1 cm distal to the PPF site. The distal femur was reamed with sized tapered reamers until the cancellous bone at the proximal entry of the distal segment, visible under direct visualization, was adequately removed, leaving the cortical bone intact. Due to the quality of bone, large diameter of the canal, and the absence of a converging cortex, long cementless stems designed to fit the diaphysis did not achieve enough scratch fit within the distal canal. To address this, we decided to use cement for the fixation of the distal part of the stem. To ensure that cement did not enter the fracture site, the stem was cemented to the distal segment. Any excess cement was meticulously removed before proceeding further. After achieving joint reduction, the remaining fracture fragments were positioned around the stem. To achieve a proper cementing technique, the distal femoral canal was closed beyond the length of the stem using absorbable gelatin sponge (Gelfoam, Pfizer, New York, NY) wrapped in Surgicel (Original, Ethicon Inc, Bridgewater, NJ). Pressurized cement was then introduced into the distal canal, providing a foundation for stable stem fixation. A diaphyseal fitting long cementless stem (Wagner SL, Zimmer; 265 mm in length, 17 mm in diameter, with a 28-mm head) was inserted in the distal part. After the joint reduction, the proximal fracture fragments were reduced around the distally fixed stem and stabilized with 2 wires. The objective of this approach was to provide initial stability through cement fixation, allowing for eventual fracture union and osteointegration of the proximal segment around the cementless stem ( Fig. 2 ). Figure 2 Postoperative radiograph of case 1.

The wound was closed in layers, and dressing was applied. Postoperatively, the patient was mobilized on the first day, with weight-bearing as tolerated. She was discharged on postoperative day 3 and prescribed 80 mg of aspirin every 12 hours for 1 month as thromboprophylaxis.
Follow-up
Postoperative radiographs were obtained on the day of surgery, then at 4 ,8, 12, and 24 weeks postoperatively. No evidence of bone resorption or heterotopic ossification was noted. The patient showed accelerated weight-bearing without extension of the PPF or development of new fractures. Final radiographs showed successful bony ingrowth in the proximal part of the stem ( Fig. 2 ). The last follow-up visit was conducted remotely at 11 months postoperatively, as the patient was unable to return for an in-person visit due to the distance. During this follow-up, the patient reported no complaints of complications, pain, or difficulty with ambulation.
Case 2
A 65-year-old male presented with complaints of right hip pain and limping. The patient had a history of pelvic osteotomy 45 years prior for Perthes disease, followed by a THA 28 years ago. Clinical examination revealed a 4-cm shortening of the right lower extremity. Levels of erythrocyte sedimentation rate and C-reactive protein were assessed to rule out infection. Radiographs showed a loose acetabular cup (Paprosky type 2a), a loose femoral stem (Paprosky type 3a), and a PPF classified as type B3 according to the Vancouver classification ( Fig. 3 ). Figure 3 Preoperative radiograph of case 2.

Surgical procedure
A revision THA was planned and performed under general anesthesia with the patient in the lateral position, utilizing a lateral approach. The first step involved removal of the polyethylene acetabular liner. Bone grafting was carried out at the acetabular site, after which a 25 × 54-mm highly porous tantalum augment (Trabecular Metal, Zimmer Biomet, Warsaw, IN) was impacted into place. A 64-mm acetabular component with a highly porous trabecular tantalum fixation surface (Continuum Acetabular System, Zimmer Inc, Warsaw, IN) was then screwed into the proper position. Attention was then directed to the femoral component. The femoral stem and cement mantle were removed through the PPF site. To prevent further fracture propagation during reaming, a prophylactic cerclage wire was placed 1 cm distal to the most inferior point of the PPF. The distal femur was reamed using tapered reamers. Due to the compromised isthmus, dilated femoral canal, and the absence of a convergent cortex, a long cementless stem designed for diaphyseal fixation did not achieve a complete scratch fit. To address this, the distal canal was blocked 2 cm longer than the stem length using an absorbable gelatin sponge (Gelfoam) wrapped in Surgicel. Cement was then pressurized into the distal canal, and a long cementless stem (265 mm in length, 20 mm in diameter) was inserted. Following joint reduction, the proximal fracture fragments were aligned and secured with cables around the femoral stem. The greater trochanter and abductor muscles were repaired using a fiber wire. Finally, the wound was closed in layers ( Fig. 4 ). Figure 4 Final follow-up radiograph of case 2.

Postoperatively, partial weight-bearing was allowed on the first postoperative day.
Complications and management
Three months after the surgery, the patient experienced a hip dislocation. A closed reduction was performed under general anesthesia. Post-reduction radiographs confirmed proper placement of the femoral head within the acetabular shell. Due to persistent abductor weakness, a decision was made to revise the acetabular liner to a 36-mm Trilogy constrained liner (Biomet, Warsaw, IN) to prevent further dislocations.
Follow-up
The patient was followed up for 35 months. Radiographs demonstrated successful bony ingrowth in the proximal part of the femoral stem, with no evidence of complications such as loosening, fracture extension, or infection ( Fig. 4 ).
It is important to clarify that the technique utilized in this case report is classified as off-label due to a cementless stem being inserted with a partial cementation. Utilization of this technique is experimental, and further follow-up is necessary to validate this off-label use of the implant.
Written informed consent was obtained from both patients for the publication of this case report.
Discussion
Periprosthetic fractures following THA pose a substantial challenge to healthcare providers, often requiring urgent and complex management. The literature consistently highlights the elevated risks of complications, reoperations, and increased early mortality rates following PPF, which are associated with poor clinical outcomes and a significant reduction in patients' quality of life. The primary goals of treating PPF are to ensure joint stability, promote fracture healing, and restore the patient’s pre-injury functional level [ [13] , [14] , [15] , [16] ].
However, certain factors complicate the revision of THA. One key challenge is managing PPF in patients with poor bone quality, which can affect treatment options, surgical approach, and the choice of revision prosthesis. Limited cortical fixation, difficulties in removing cement, and potential stress risers further complicate the process [ [17] , [18] , [19] ]. Achieving long-term femoral stem stability is essential to prevent secondary revision and restore previous levels of activity. Nonetheless, in patients with compromised bone quality, securing stable proximal and distal fixation is difficult due to deficient metaphyseal and/or diaphyseal bone stock [ 20 ].
Various techniques and implants have been introduced for femoral stem revision, including impaction bone grafting with a cemented polished stem, extensively porous-coated stems, cortical strut allografts, and distal cementless fixation using cortical strut allografts with modular or monoblock femoral stems, or even megaprostheses [ 17 , [20] , [21] , [22] , [23] , [24] , [25] , [26] , [27] ]. A comprehensive review of these techniques and implants by Ali et al. reported that each approach offers distinct advantages and disadvantages, but none has proven entirely successful in addressing severe bone stock deficiencies [ 28 ].
There remains considerable debate regarding the optimal surgical method and implant choice to maximize prosthesis longevity. Some authors recommend that the femoral stem should bypass the bone defect by at least 2 cortical thickness. For long cementless stems, achieving sufficient diaphyseal press-fit fixation requires 4-7 cm of intact isthmus [ 20 , 28 ]. In cases where the isthmus is compromised by fracture comminution or osteoporosis, distal locking or cemented stems are preferred. However, biomechanical and clinical studies have indicated that cemented stems have higher failure rates than cementless implants, making them a less-suitable option for femoral stem revisions [ [29] , [30] , [31] , [32] ].
In the current technique described, the surgeons aimed to combine the advantages of both cemented and cementless long femoral stems. Cemented stems were avoided due to concerns about bone cement leakage, which could impair fracture healing. Instead, a long monoblock stem was used to bypass the fracture site and bone defects, with cement applied only for distal diaphyseal fixation. This approach allowed for osteogenesis and osteointegration in the proximal regions, resulting in successful fracture union between the proximal and distal segments. At 35 months postoperatively, radiographs showed good fixation of the femoral stems, and the patients were able to walk independently with satisfactory functional outcomes. Further investigation into the long-term outcomes of this technique with a larger cohort is recommended to better confirm its effectiveness and to provide a more comprehensive understanding of potential complications and sustained benefits over time.
Conclusions
This report highlights a novel approach to treating Vancouver Type B3 PPFs with poor bone stock. Using a monoblock cementless long-stem prosthesis with distal cement fixation proved to be a viable technique in achieving stable fixation, promoting fracture healing, and maintaining successful bony ingrowth. The procedure allowed for early mobilization, minimized complications, and addressed the challenges posed by poor bone quality. Our findings suggest that this method could be a promising option for managing similar cases.
Conflicts of interest
The authors declare there are no conflicts of interest.
For full disclosure statements refer to https://doi.org/10.1016/j.artd.2025.101645 .
Informed patient consent
The author(s) confirm that written informed consent has been obtained from the involved patient(s) or if appropriate from the parent, guardian, power of attorney of the involved patient(s); and, they have given approval for this information to be published in this case report (series).
CRediT authorship contribution statement
Moein Akbari Javar: Writing – original draft, Project administration, Methodology. Sina Esmaeili: Writing – original draft, Methodology. Shahram Shokraneh: Writing – original draft, Conceptualization. Mohammad Ghorbanzadeh: Writing – review & editing, Writing – original draft. Seyed Mohammad Javad Mortazavi: Writing – review & editing, Project administration, Conceptualization.
References
1 Rayan F. Haddad F. Periprosthetic femoral fractures in total hip arthroplasty - a review Hip Int 20 2010 418 426 10.1177/112070001002000402 21157744
2 Boddice T. Harrison P. Anthony C. Ng A.B.Y. Periprosthetic fractures around total hip replacement-is there a rush to fix? J Clin Med 12 2023 3512 10.3390/jcm12103512 PMC10219206 37240618
3 Tsiridis E. Haddad F.S. Gie G.A. The management of periprosthetic femoral fractures around hip replacements Injury 34 2003 95 105 10.1016/s0020-1383(02)00257-7 12565015
4 Schwarzkopf R. Oni J.K. Marwin S.E. Total hip arthroplasty periprosthetic femoral fractures: a review of classification and current treatment Bull Hosp Jt Dis (2013) 71 2013 68 78 24032586
5 Kim Y. Tanaka C. Tada H. Kanoe H. Shirai T. Treatment of periprosthetic femoral fractures after femoral revision using a long stem BMC Musculoskelet Disord 16 2015 113 10.1186/s12891-015-0565-7 25958328 PMC4494722
6 Sloan M. Premkumar A. Sheth N.P. Projected volume of primary total joint arthroplasty in the U.S., 2014 to 2030 J Bone Joint Surg Am 100 2018 1455 1460 10.2106/jbjs.17.01617 30180053
7 Duncan C.P. Masri B.A. Fractures of the femur after hip replacement Instr Course Lect 44 1995 293 304 7797866
8 Fink B. Grossmann A. Singer J. Hip revision arthroplasty in periprosthetic fractures of vancouver type B2 and B3 J Orthop Trauma 26 2012 206 211 10.1097/BOT.0b013e318220a94f 22011633
9 Naqvi G.A. Baig S.A. Awan N. Interobserver and intraobserver reliability and validity of the Vancouver classification system of periprosthetic femoral fractures after hip arthroplasty J Arthroplasty 27 2012 1047 1050 10.1016/j.arth.2011.11.021 22425302
10 Masri B.A. Meek R.M. Duncan C.P. Periprosthetic fractures evaluation and treatment Clin Orthop Relat Res 2004 80 95 10.1097/00003086-200403000-00012 15057082
11 Fink B. Fuerst M. Singer J. Periprosthetic fractures of the femur associated with hip arthroplasty Arch Orthop Trauma Surg 125 2005 433 442 10.1007/s00402-005-0828-0 15999276
12 Haidukewych G.J. Langford J. Liporace F.A. Revision for periprosthetic fractures of the hip and knee J Bone Joint Surg Am 95 2013 368 376 23553235
13 Abdel M.P. Cottino U. Mabry T.M. Management of periprosthetic femoral fractures following total hip arthroplasty: a review Int Orthop 39 2015 2005 2010 10.1007/s00264-015-2979-0 26318883
14 Tangsataporn S. Safir O.A. Vincent A.D. Abdelbary H. Gross A.E. Kuzyk P.R. Risk factors for subsidence of a modular tapered femoral stem used for revision total hip arthroplasty J Arthroplasty 30 2015 1030 1034 10.1016/j.arth.2015.01.009 25701193
15 Lindahl H. Malchau H. Herberts P. Garellick G. Periprosthetic femoral fractures classification and demographics of 1049 periprosthetic femoral fractures from the Swedish National Hip Arthroplasty Register J Arthroplasty 20 2005 857 865 10.1016/j.arth.2005.02.001 16230235
16 Lindahl H. Malchau H. Odén A. Garellick G. Risk factors for failure after treatment of a periprosthetic fracture of the femur J Bone Joint Surg Br 88 2006 26 30 10.1302/0301-620x.88b1.17029 16365115
17 Tetreault M.W. Shukla S.K. Yi P.H. Sporer S.M. Della Valle C.J. Are short fully coated stems adequate for "simple" femoral revisions? Clin Orthop Relat Res 472 2014 577 583 10.1007/s11999-013-3167-4 23846608 PMC3890204
18 Gausden E.B. Wellman D.S. Biomechanics of periprosthetic fixation: Plates, nails, cables, and allografts J Orthop Trauma 33 Suppl 6 2019 S1 S4 10.1097/bot.0000000000001569 31404036
19 Sadoghi P. Liebensteiner M. Agreiter M. Leithner A. Böhler N. Labek G. Revision surgery after total joint arthroplasty: a complication-based analysis using worldwide arthroplasty registers J Arthroplasty 28 2013 1329 1332 10.1016/j.arth.2013.01.012 23602418
20 Ding Z.C. Ling T.X. Yuan M.C. Qin Y.Z. Mou P. Wang H.Y. Minimum 8-year follow-up of revision THA with severe femoral bone defects using extensively porous-coated stems and cortical strut allografts BMC Musculoskelet Disord 21 2020 218 10.1186/s12891-020-03250-0 32268894 PMC7140549
21 Kim Y.H. Park J.W. Kim J.S. Rastogi D. High survivorship with cementless stems and cortical strut allografts for large femoral bone defects in revision THA Clin Orthop Relat Res 473 2015 2990 3000 10.1007/s11999-015-4358-y 26013152 PMC4523544
22 Haddad F.S. Duncan C.P. Berry D.J. Lewallen D.G. Gross A.E. Chandler H.P. Periprosthetic femoral fractures around well-fixed implants: use of cortical onlay allografts with or without a plate J Bone Joint Surg Am 84 2002 945 950 12063328
23 Lim C.T. Amanatullah D.F. Huddleston J.I. 3rd Hwang K.L. Maloney W.J. Goodman S.B. Cortical strut allograft support of modular femoral junctions during revision total hip arthroplasty J Arthroplasty 32 2017 1586 1592 10.1016/j.arth.2016.12.011 28130016
24 Schreurs B.W. Arts J.J. Verdonschot N. Buma P. Slooff T.J. Gardeniers J.W. Femoral component revision with use of impaction bone-grafting and a cemented polished stem. Surgical technique J Bone Joint Surg Am 88 Suppl 1 2006 259 274 10.2106/jbjs.F.00340 16951098
25 Wilson M.J. Hook S. Whitehouse S.L. Timperley A.J. Gie G.A. Femoral impaction bone grafting in revision hip arthroplasty: 705 cases from the originating centre Bone Joint J 98-b 2016 1611 1619 10.1302/0301-620x.98b12.37414 27909122
26 Holt G. Hook S. Hubble M. Revision total hip arthroplasty: the femoral side using cemented implants Int Orthop 35 2011 267 273 10.1007/s00264-010-1167-5 21165618 PMC3032104
27 Astore F. Molho N.M. Piccaluga F. Comba F. Slullitel P.A. Buttaro M.A. Impaction bone grafting for severe femoral bone loss: surgical technique in revision total hip arthroplasty JBJS Essent Surg Tech 12 2022 e20.00043 10.2106/jbjs.St.20.00043 PMC9173563 35692723
28 Ali E. Howard L.C. Neufeld M.E. Masri B.A. Treatment of femoral bone loss in revision total hip arthroplasty: a clinical practice review Ann Jt 9 2024 4 10.21037/aoj-23-31 38529292 PMC10929365
29 Ramavath A. Lamb J.N. Palan J. Pandit H.G. Jain S. Postoperative periprosthetic femoral fracture around total hip replacements: current concepts and clinical outcomes EFORT Open Rev 5 2020 558 567 10.1302/2058-5241.5.200003 33072408 PMC7528669
30 Pellicci P.M. Wilson P.D. Jr. Sledge C.B. Salvati E.A. Ranawat C.S. Poss R. Long-term results of revision total hip replacement. A follow-up report J Bone Joint Surg Am 67 1985 513 516 3980494
31 Sheth N.P. Melnic C.M. Rozell J.C. Paprosky W.G. Management of severe femoral bone loss in revision total hip arthroplasty Orthop Clin North Am 46 2015 329 342 10.1016/j.ocl.2015.02.002 26043047
32 Kavanagh B.F. Ilstrup D.M. Fitzgerald R.H. Jr. Revision total hip arthroplasty J Bone Joint Surg Am 67 1985 517 526 3980495
Supplementary data
Conflict of Interest Statement for Akbari Javar Conflict of Interest Statement for Esmaeili Conflict of Interest Statement for Ghorbanzadeh Conflict of Interest Statement for Javad Mortazavi Conflict of Interest Statement for Shokraneh