MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ajt.14755

Медицинская библиотека · American journal of transplantation : official journal of the American Society of Transplantation and the American Society of Transplant Surgeons · 2018

Burden and consequences of retained cardiovascular implantable electronic device lead fragments after heart transplantation.

Alvarez Paulino A, Sperry Brett W, Perez Antonio L, Varian Kenneth, Raymond Timothy, Tong Michael, Hussein Ayman A, Taylor David O

СтатьяПеревод в очереди

Аннотация

We performed a retrospective review of 402 consecutive patients who underwent heart transplantation at our institution between January 2009 and March 2017. A retained cardiovascular implantable electronic device (CIED) fragment was identified after transplantation in 49 of the 301 patients (16.2%) with CIED at baseline. Patients with retained fragments had leads with longer dwell times (median 2596 [1982, 3389] vs 1384 [610, 2202] days, P < .001), higher prevalence of previously abandoned leads (14.3% vs 2.8%, P = .003), and dual-coil defibrillator leads (98% vs 81%, P = .001) compared with patients without retained fragments. Five patients (10%) with retained CIED fragments underwent magnetic resonance imaging without adverse events. There was no difference in overall mortality between patients with and without CIED fragments (12% vs 11%, P = .81) Patients with retained fragments located in the superior vena cava had significantly higher fluoroscopic times (3.3 vs 2.9 minutes, P = .024) during subsequent endomyocardial biopsies. In a competing risk analysis, presence of a retained CIED fragment was associated with upper extremity deep venous thrombosis (sub hazard ratio [HR] 2.19, 95% confidence interval [CI] 1.17-4.10, P = .014) but not bloodstream infection after adjusting for potential confounders. In summary, retained CIED fragments are common after heart transplantation, and are associated with longer radiation exposure during biopsy procedures and upper extremity deep venous thrombosis.

Для цитирования: Alvarez Paulino A, Sperry Brett W, Perez Antonio L, Varian Kenneth, Raymond Timothy, Tong Michael, Hussein Ayman A, Taylor David O. Burden and consequences of retained cardiovascular implantable electronic device lead fragments after heart transplantation.. American journal of transplantation : official journal of the American Society of Transplantation and the American Society of Transplant Surgeons. 2018. DOI: 10.1111/ajt.14755.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.